Predictika · Commercial water heating quotes
An AI sales agent prepares a quote for a building that needs commercial hot water: Sensei commercial tankless units, Demand Duo hybrid systems, or wall-mount and free-standing Tankless Rack Systems, with common venting, circulation pumps and commercial accessories. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of Rinnai America's published suggested list prices and returns a verdict, every reason and the figures it computed.
This validator models a quote for Rinnai America commercial and high-flow water heating products as listed in the Rinnai America 2020 Suggested List Price (USD) price list, effective March 6, 2020, not just the scenarios shown below.
Any commercial tankless quote that touches these products is in scope — not only the scenarios pictured here. Not covered: products and accessories that the price list does not show here (other water heaters, residential models, parts, venting beyond the starter kits and wall terminals), mixed racks in one freight calculation, taxes, dealer discounts and newer price lists. The prices are Rinnai America's 2020 suggested list prices, read from the published list, and may differ from current prices.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Only the systems the price list shows, by family and size | Only with workarounds Each rack size exists only for some mounts and each Demand Duo only in three tank and input pairings, so a rules-based CPQ needs a table or a rule per combination, edited whenever the price list changes. | The family and size are matched to the published rows on every call, and a missing row is a finding. |
| Rack freight that depends on the position of each rack | Only with care The first, second, third and later racks have different rates for each rack model, which needs a separate price rule per tier. | The tiers are computed from the quantity on every call and added to the total. |
| A freight of 1.25 percent of the vent list | Only with care A percentage of a subtotal that is itself built from a kit and a number of terminals has to be recomputed whenever either changes. | The vent subtotal and its freight are computed in the same pass as everything else. |
| Accessories that must fit each other | Only with care A flange kit that matches a pump series, and wall terminals that need a vent kit, are dependencies between optional lines. | The pump, the flange kit, the vent kit and the terminals are compared together, in any order. |
| Stated total and stated heating input | Only with care The stated figures are derived from the chosen row, the quantity, freight and accessories, so a rule has to recompute them and compare. | Both stated figures are fields in the request, compared with the computed ones on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The price list has no system with the selected family and size. |
| 2 | The Demand Duo hybrid systems in the price list are indoor models only. |
| 3 | The quote has 0 systems; at least 1 is needed. |
| 4 | The quote needs 100,000 Btu/h of maximum heating input; the selected systems give 0 Btu/h in total. |
| 5 | The quote needs 796,001 Btu/h of maximum heating input; the selected systems give 796,000 Btu/h in total. |
| 6 | The quote states 800,000 Btu/h of total heating input; the selected systems give 796,000. |
| 7 | The quote states a total of $15,000.00; the list prices give $16,539.00. |
| 8 | The price list has common vent kits for 3, 4 and 6 inch vents; the quote has 5 inches. |
| 9 | The quote has 2 wall terminals but no common vent kit. |
| 10 | The flange kit does not fit the selected pump; the price list has a flange kit for the UPS 26 series pumps and another for the UPS 40 series pump. |
| 11 | An accessory quantity in the quote is below zero. |
| 12 | The prices are the Rinnai America suggested list prices effective March 6, 2020, which Rinnai says are subject to change without notice; a person should confirm they are still current. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 of the 3-unit wall-mount Tankless Rack System (model TRW03CUiN, interior, natural gas) for Harborview Suites, a hotel, which needs 1,000,000 Btu/h of heating input, with a 4 inch direct vent common vent starter kit with 2 wall terminals, a Grundfos UPS 26-150 circulation pump with the 26 series flange kit, 2 ScaleCutter systems and 2 additional commercial controllers. The prices have been checked against the current Rinnai list. The quote states a total of $20,682.00 and 1,194,000 Btu/h of total heating input. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 of the 3-unit wall-mount Tankless Rack System (model TRW03CUiN, interior, natural gas) for Harborview Suites, a hotel, which needs 1,000,000 Btu/h of heating input, with a 4 inch direct vent common vent starter kit with 2 wall terminals, a Grundfos UPS 26-150 circulation pump with the 26 series flange kit, 2 ScaleCutter systems and 2 additional commercial controllers. The prices have been checked against the current Rinnai list. The quote states a total of $21,350.7625 and 1,194,000 Btu/h of total heating input. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 1 of the 4-unit free-standing Tankless Rack System (model TRS04CUiN, interior, natural gas) for Lakeside Medical Plaza, an outpatient clinic building, which needs 700,000 Btu/h of heating input, with 3 wall terminals, a Grundfos UPS 40-160 circulation pump with the 26 series flange kit, 1 ScaleCutter system, a commercial neutralization tank, 2 additional commercial controllers and 1 ST119 storage tank. The quote states a total of $22,488.00 and 796,000 Btu/h of total heating input. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 1 of the 4-unit free-standing Tankless Rack System (model TRS04CUiN, interior, natural gas) for Lakeside Medical Plaza, an outpatient clinic building, which needs 700,000 Btu/h of heating input, with a 4 inch direct vent common vent starter kit with 3 wall terminals, a Grundfos UPS 40-160 circulation pump with the 40 series flange kit, 1 ScaleCutter system, a commercial neutralization tank, 2 additional commercial controllers and 1 ST119 storage tank. The quote states a total of $22,868.725 and 796,000 Btu/h of total heating input. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 1 of the 4-unit free-standing Tankless Rack System (model TRS04CUiN, interior, natural gas) for Lakeside Medical Plaza, an outpatient clinic building, which needs 700,000 Btu/h of heating input, with a 4 inch direct vent common vent starter kit with 3 wall terminals, a Grundfos UPS 40-160 circulation pump with the 40 series flange kit, 1 ScaleCutter system, a commercial neutralization tank, 2 additional commercial controllers and 1 ST119 storage tank. The prices have been checked against the current Rinnai list. The quote states a total of $22,868.725 and 796,000 Btu/h of total heating input. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 of the Demand Duo commercial hybrid water heating system, 119 gallon tank, 398,000 Btu/h (model CHS398100CUeN, exterior, natural gas) for Birchwood Elementary School, which needs 700,000 Btu/h of heating input, with a 3 inch room air common vent starter kit with 1 wall terminal, a Grundfos UPS 26-99 circulation pump, 2 ScaleCutter systems, a commercial neutralization tank and 2 additional commercial controllers. The prices have been checked against the current Rinnai list. The quote states a total of $32,649.1875 and 796,000 Btu/h of total heating input. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 of the Demand Duo commercial hybrid water heating system, 119 gallon tank, 398,000 Btu/h (model CHS398100CUiN, interior, natural gas) for Birchwood Elementary School, which needs 700,000 Btu/h of heating input, with a 3 inch room air common vent starter kit with 1 wall terminal, a Grundfos UPS 26-99 circulation pump, 2 ScaleCutter systems, a commercial neutralization tank and 2 additional commercial controllers. The prices have been checked against the current Rinnai list. The quote states a total of $32,649.1875 and 796,000 Btu/h of total heating input. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.