Predictika · RF cable assembly orders
An AI sales agent prepares an order for standard RTK Flex coaxial cable assemblies from a public catalogue: the connector pair, the length, the frequency the application needs, the power and the bend radius it will run at. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the catalogue's published figures and returns a verdict, every reason and the figures it computed.
This validator models orders for 19 standard assemblies in Rosenberger's public RFlex cable assembly catalogue, not just the scenarios shown below.
Any order for these assemblies that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Rosenberger publishes none; its configurator ends in a quote request, so this validator produces no price build-up or line-item quote), the Quick-Lock and Push-On variants, the SMP and right-angle SMA+ assemblies, the 2.92 mm to 2.92 mm and right-angle high-frequency assemblies, pair-matched and delay-matched options, other cable families and connectors, and custom assemblies.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A frequency limit that depends on the connector pair | Only with care The rating of a high-frequency assembly depends on which connectors are on its ends, so it needs a rule per pair, kept in step with the catalogue. | The rating is looked up from the chosen pair and compared with the application on every call. |
| A rating the agent states that disagrees with the catalogue | Only with workarounds The figure the agent states is free text or a separate field, so it takes an extra rule that compares it with the assembly's own rating. | The stated rating is part of the request and is compared with the catalogue figure on every call. |
| Power limits that fall with frequency | Only with workarounds A rating table by frequency band needs a lookup rule, and the check has to use the band at or above the operating frequency. | The band is derived from the frequency and the power is compared with its rating on every call. |
| Lengths that are standard only for some assemblies | Only with care Each assembly has its own list of standard lengths, so each needs its own rule, and every catalogue change adds more. | The length is compared with the list for the chosen assembly; anything else goes to a person. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The application needs 37 GHz but the selected assembly is rated DC to 36 GHz. |
| 2 | The application needs 19 GHz but the selected assembly is rated DC to 18 GHz. |
| 3 | The application needs 71 GHz but the selected assembly is rated DC to 70 GHz. |
| 4 | The application needs 50 GHz but the selected assembly is rated DC to 40 GHz. |
| 5 | The application needs 66 GHz but the selected assembly is rated DC to 65 GHz. |
| 6 | The quote states a rating of DC to 36 GHz, but the catalogue lists DC to 18 GHz for the selected assembly. |
| 7 | The planned bend radius of 0.99 inches is below the catalogue minimum one-time bend radius of 1.00 inches for this cable. |
| 8 | The planned bend radius of 1.00 inches is above the minimum one-time bend radius but below the preferred radius of 4.00 inches; a person should confirm the routing. |
| 9 | The planned bend radius of 0.74 inches is below the catalogue minimum one-time bend radius of 0.75 inches for this cable. |
| 10 | The planned bend radius of 0.75 inches is above the minimum one-time bend radius but below the preferred radius of 2.00 inches; a person should confirm the routing. |
| 11 | The length of 1,000 mm is not one of the standard catalogue lengths for this assembly; the public catalogue does not say whether a custom length can be supplied, so a person should confirm it. |
| 12 | The length of 6,100 mm is not one of the standard catalogue lengths for this assembly; the public catalogue does not say whether a custom length can be supplied, so a person should confirm it. |
| 13 | The application runs 61 W continuous wave but the catalogue rating for this cable at that frequency is 60 W. |
| 14 | The application runs 73 W continuous wave but the catalogue rating for this cable at that frequency is 72 W. |
| 15 | The catalogue publishes continuous-wave power ratings only for RTK Flex 402 at 2 GHz and above; a person should confirm 100 W for this cable and frequency. |
| 16 | The catalogue publishes continuous-wave power ratings only for RTK Flex 402 at 2 GHz and above; a person should confirm 50 W for this cable and frequency. |
| 17 | The quantity is 0; an order needs at least one assembly. |
| 18 | The application needs 40 GHz but the selected assembly is rated DC to 36 GHz. |
| 19 | The quote states a rating of DC to 40 GHz, but the catalogue lists DC to 36 GHz for the selected assembly. |
| 20 | The planned bend radius of 0.50 inches is below the catalogue minimum one-time bend radius of 0.75 inches for this cable. |
| 21 | The application needs 20 GHz but the selected assembly is rated DC to 18 GHz. |
| 22 | The planned bend radius of 2.00 inches is above the minimum one-time bend radius but below the preferred radius of 4.00 inches; a person should confirm the routing. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 80 RTK Flex 402 SMA male to TNC male cable assemblies, 915 mm (36.0 in) long, for an application that runs at 12 GHz at 120 W continuous wave, with a planned bend radius of 0.60 inches. The quote states a rating of DC to 18 GHz. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 80 RTK Flex 402 SMA male to TNC male cable assemblies, 915 mm (36.0 in) long, for an application that runs at 12 GHz at 60 W continuous wave, with a planned bend radius of 1.00 inches. The quote states a rating of DC to 18 GHz. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 80 RTK Flex 402 SMA male to TNC male cable assemblies, 915 mm (36.0 in) long, for an application that runs at 12 GHz at 60 W continuous wave, with a planned bend radius of 4.00 inches. The quote states a rating of DC to 18 GHz. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 200 RTK Flex 402 SMA male to SMA male cable assemblies, 915 mm (36.0 in) long, for an application that runs at 24 GHz, with a planned bend radius of 4.00 inches. The quote states a rating of DC to 36 GHz. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 200 RTK Flex 405 SMA+ male to SMA+ male cable assemblies, 915 mm (36.0 in) long, for an application that runs at 24 GHz, with a planned bend radius of 4.00 inches. The quote states a rating of DC to 36 GHz. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 40 RTK Flex 047 2.92 mm male to WSMP female cable assemblies, 203 mm (8.0 in) long, for an application that runs at 50 GHz, with a planned bend radius of 4.00 inches. The quote states a rating of DC to 70 GHz. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 RTK Flex 047 1.85 mm male to WSMP female cable assemblies, 203 mm (8.0 in) long, for an application that runs at 50 GHz, with a planned bend radius of 4.00 inches. The quote states a rating of DC to 70 GHz. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.