Predictika · Sunny Tripower CORE2 string design
An AI sales agent prepares an order for the Sunny Tripower CORE2 STP 110-60 together with the string design behind it: modules per string, strings and MPP trackers, site temperatures and grid. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the inverter limits and returns a verdict, every reason and the figures it computed.
This validator models orders for the SMA Sunny Tripower CORE2 STP 110-60 and the string design that goes with it, not just the scenarios shown below.
Any STP 110-60 design that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (this validator produces no price build-up or line-item quote), other SMA inverters such as the Sunny Boy, Sunny Tripower X or Smart Energy models, storage and the Sunny Home Manager, and module-level or wiring details. The cold-temperature voltage check and the approval rules are modeled from standard PV practice rather than taken from SMA documents (see the footnote).
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A string voltage that depends on the coldest site day | Only with workarounds The open-circuit voltage rises as it gets colder, by the module temperature coefficient. That needs a calculation from several fields and a comparison with 1100 V, which rule screens handle poorly. | The module voltage, temperature coefficient, modules per string and coldest temperature are combined on every call and compared with 1100 V. |
| Tracker current that depends on how strings are spread | Only with workarounds Whether a tracker carries one string or two depends on the string and tracker counts; the current limits must then be checked against that worst case. | The worst-case strings per tracker is computed and both current limits are checked against it. |
| Array power that must match the stated figure | Only with care A stated figure is a free-entry field; a rule can compare it with a computed total, but someone has to write and maintain that comparison. | The stated figure travels with the design and is compared with the computed figure on every call. |
| A working voltage window with a start voltage and an MPP range | Only with care Three different voltage limits apply to the same value, some blocking and some only worth a look. They can be written, but each needs its own rule and message. | Each limit is its own finding, with blocks and approvals reported together. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.
| 1 | The STP 110-60 has 12 independent MPP trackers; the design uses 13. |
| 2 | The STP 110-60 has 12 independent MPP trackers; the design uses 0. |
| 3 | Each MPP tracker takes 1 or 2 strings; 16 strings cannot be connected to 0 tracker(s). |
| 4 | Each MPP tracker takes 1 or 2 strings; 25 strings cannot be connected to 12 tracker(s). |
| 5 | The PV array per inverter is 247,500 Wp; the maximum is 165,000 Wp STC. |
| 6 | The PV array per inverter is 237,600 Wp; the maximum is 165,000 Wp STC. |
| 7 | The design counts 12 trackers in use but has only 10 strings, so a tracker would have no string. |
| 8 | 21 modules in series reach more than the 1,100 V maximum input voltage on a cold day (module open-circuit voltage 50 V, coldest day -10 degrees C). |
| 9 | A string working at 882 V is outside the 500 V to 800 V MPP voltage range, so a person should confirm the expected yield. |
| 10 | A string working at 840 V is outside the 500 V to 800 V MPP voltage range, so a person should confirm the expected yield. |
| 11 | 20 modules in series reach more than the 1,100 V maximum input voltage on a cold day (module open-circuit voltage 50 V, coldest day -20 degrees C). |
| 12 | A string of 5 modules works at 210 V, below the 250 V start input voltage. |
| 13 | A string working at 210 V is outside the 500 V to 800 V MPP voltage range, so a person should confirm the expected yield. |
| 14 | The strings on one tracker carry 28 A of working current; the maximum input current per MPP tracker is 26 A. |
| 15 | The strings on one tracker reach 42 A of short-circuit current; the maximum per MPP tracker is 40 A. |
| 16 | The operating temperature range is -30 to +60 degrees C; the site runs from -35 to 40 degrees C. |
| 17 | The operating temperature range is -30 to +60 degrees C; the site runs from -10 to 65 degrees C. |
| 18 | The AC voltage range is 320 V to 460 V (400 V nominal); the site grid is 300 V. |
| 19 | The AC voltage range is 320 V to 460 V (400 V nominal); the site grid is 480 V. |
| 20 | The inverter supports 50 Hz and 60 Hz grids; the site grid is 55 Hz. |
| 21 | The warranty is 5 years as standard, or 10, 15 or 20 years optional; the order has 7 years. |
| 22 | The order must include at least one inverter; it has 0. |
| 23 | A string working at 462 V is outside the 500 V to 800 V MPP voltage range, so a person should confirm the expected yield. |
| 24 | 10 inverters is a project order; a person should confirm project terms and delivery. |
| 25 | The order states a PV array of 165,000 Wp per inverter, but the strings and modules add up to 158,400 Wp. |
| 26 | The order states 14 A of short-circuit current per tracker, but the design gives 28 A. |
| 27 | The STP 110-60 has 12 independent MPP trackers; the design uses 14. |
| 28 | Each MPP tracker takes 1 or 2 strings; 30 strings cannot be connected to 14 tracker(s). |
| 29 | 22 modules in series reach more than the 1,100 V maximum input voltage on a cold day (module open-circuit voltage 50 V, coldest day -10 degrees C). |
| 30 | The strings on one tracker carry 30 A of working current; the maximum input current per MPP tracker is 26 A. |
| 31 | The PV array per inverter is 363,000 Wp; the maximum is 165,000 Wp STC. |
| 32 | The warranty is 5 years as standard, or 10, 15 or 20 years optional; the order has 8 years. |
| 33 | The order states a PV array of 100 Wp per inverter, but the strings and modules add up to 363,000 Wp. |
| 34 | A string working at 924 V is outside the 500 V to 800 V MPP voltage range, so a person should confirm the expected yield. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please order 1 Sunny Tripower CORE2 STP 110-60 inverter for 24 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 21 A short-circuit current and 15 A working current. The site runs from -10 to 40 degrees C on a 400 V, 50 Hz grid, with a 5-year warranty. The order states a PV array of 237,600 Wp per inverter and 42 A of short-circuit current per tracker. It is ready to send.
Verdict: Blocked.
The agent's request. Please order 1 Sunny Tripower CORE2 STP 110-60 inverter for 24 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 15 A short-circuit current and 13 A working current. The site runs from -10 to 40 degrees C on a 400 V, 50 Hz grid, with a 5-year warranty. The order states a PV array of 237,600 Wp per inverter and 30 A of short-circuit current per tracker. It is ready to send.
Verdict: Blocked.
The agent's request. Please order 1 Sunny Tripower CORE2 STP 110-60 inverter for 16 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 14 A short-circuit current and 13 A working current. The site runs from -10 to 40 degrees C on a 400 V, 50 Hz grid, with a 5-year warranty. The order states a PV array of 158,400 Wp per inverter and 28 A of short-circuit current per tracker. It is ready to send.
Verdict: Allowed.
The agent's request. Please order 1 Sunny Tripower CORE2 STP 110-60 inverter for 14 strings of 22 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 14 A short-circuit current and 13 A working current. The site runs from -20 to 40 degrees C on a 400 V, 50 Hz grid, with a 5-year warranty. The order states a PV array of 169,400 Wp per inverter and 28 A of short-circuit current per tracker. It is ready to send.
Verdict: Blocked.
The agent's request. Please order 1 Sunny Tripower CORE2 STP 110-60 inverter for 14 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 14 A short-circuit current and 13 A working current. The site runs from -20 to 40 degrees C on a 400 V, 50 Hz grid, with a 5-year warranty. The order states a PV array of 138,600 Wp per inverter and 28 A of short-circuit current per tracker. It is ready to send.
Verdict: Allowed.
The agent's request. Please order 10 Sunny Tripower CORE2 STP 110-60 inverters for 16 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 14 A short-circuit current and 13 A working current. The site runs from -10 to 40 degrees C on a 400 V, 50 Hz grid, with a 8-year warranty. The order states a PV array of 158,400 Wp per inverter and 28 A of short-circuit current per tracker. It is ready to send.
Verdict: Blocked.
The agent's request. Please order 10 Sunny Tripower CORE2 STP 110-60 inverters for 16 strings of 18 modules over 12 MPP trackers. The modules are 550 Wp with 50 V open-circuit voltage (temperature coefficient -0.26% per kelvin), 42 V working voltage, 14 A short-circuit current and 13 A working current. The site runs from -10 to 40 degrees C on a 400 V, 50 Hz grid, with a 10-year warranty. The order states a PV array of 158,400 Wp per inverter and 28 A of short-circuit current per tracker. It is ready to send.
Verdict: Needs approval.
The text of the narrated walkthrough, step by step.