An AI sales agent configures an electricity smart metering rollout for a utility: the meter model, the communication technology, data concentrators, gas meters collected over M-Bus, the security suite and the head-end software. Before the quote goes out, the agent sends it to Predictika, which checks it against a declarative model, compares the number of meter points the agent states with the one it computes, and returns a verdict, every reason and the figures it computed.
This validator models rollout quotes for Sagemcom electricity smart meters and the systems around them, built from Sagemcom product and technology names, not just the scenarios shown below.
Any rollout quote that touches these products and rules is in scope, not only the scenarios pictured here. Product and technology names are Sagemcom's own public names. The rated currents, concentrator capacity, M-Bus limits, band rules and approval thresholds are modeled from comparable smart meters and are not Sagemcom-published rules. Not covered: prices (this validator produces no price build-up or line-item quote), gas and water meter models, the Sagemcom Dr. Neuhaus and Fröschl products, and Sagemcom broadband and audio-video products.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Concentrators that must cover the meters, and cellular meters that need none | Only with care The rule depends on the communication technology and a capacity calculation; each new technology means more rules to maintain. | The coverage is computed from the concentrators and compared with the meters, and cellular rollouts are checked the other way round. |
| Gas meters read through an electricity meter over M-Bus | Only with workarounds It depends on the gateway model, the number of gas meters and the electricity meters, across two product lines. | The gateway model and the gas meters per electricity meter are checked together. |
| Stated meter points that must equal the electricity and gas meters | Only with care A stated figure is a free-entry field; a rule can compare it with a computed one, but someone has to write and maintain that comparison. | The stated figure travels with the quote and is compared with the computed figure on every call. |
| A frequency band and a relay that depend on the technology and the security suite | Only with workarounds Each depends on a choice elsewhere on the quote, so they need cross-field rules that interact with the rest. | Every choice is in one request, so the conflict is found whichever order the choices arrive in. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 0 electricity meters; at least 1 is needed. |
| 2 | The S211 and XS212 are single-phase meters and the T211 and XT211 are three-phase meters; the selected meter does not fit the service phase. |
| 3 | A rated current of 100 A is outside what the selected meter handles in this model: 20 to 80 A for single-phase meters and 20 to 100 A for three-phase meters. |
| 4 | A rated current of 120 A is outside what the selected meter handles in this model: 20 to 80 A for single-phase meters and 20 to 100 A for three-phase meters. |
| 5 | A rated current of 10 A is outside what the selected meter handles in this model: 20 to 80 A for single-phase meters and 20 to 100 A for three-phase meters. |
| 6 | A power-line (G3-PLC, G3 Hybrid or PRIME) network sends meter data through data concentrators and the quote has 0. |
| 7 | The quote has 50,000 meters; the data concentrators serve 0 meters at 1,000 per concentrator in this model. |
| 8 | NB-IoT and LTE Cat.1 meters report straight to the head-end, so the 60 data concentrators on the quote are not needed. |
| 9 | NB-IoT and LTE Cat.1 meters report straight to the head-end, so the 5 data concentrators on the quote are not needed. |
| 10 | The quote has 50,000 meters; the data concentrators serve 49,000 meters at 1,000 per concentrator in this model. |
| 11 | PRIME is modeled in the CENELEC A band only; the FCC band is available for G3-PLC and G3 Hybrid. |
| 12 | Collecting gas meter data over M-Bus needs the XS212 or XT211 as the gateway meter in this model. |
| 13 | 20,000 gas meters are on the quote but gas data collection over M-Bus is not selected. |
| 14 | M-Bus gas collection is selected but the quote has 0 gas meters. |
| 15 | 200,001 gas meters is more than 4 per electricity meter, the M-Bus limit in this model, for 50,000 electricity meters. |
| 16 | The remote disconnect relay needs DLMS Security Suite 1 or Suite 2 for signed commands; Suite 0 is selected. |
| 17 | DLMS Security Suite 2 needs a security architect to confirm the key management and certificate set-up. |
| 18 | The Siconia MDMS needs the Siconia head-end system on the quote in this model. |
| 19 | Support runs 1 to 10 years in this model; the quote has 11 years. |
| 20 | Support runs 1 to 10 years in this model; the quote has 0 years. |
| 21 | The quote states 60,000 meter points for the head-end, but the electricity and gas meters on it make 50,000. |
| 22 | The quote states 50,000 meter points for the head-end, but the electricity and gas meters on it make 70,000. |
| 23 | A rollout of 250,000 electricity meters or more needs a program review of deliveries, spares and field staffing. |
| 24 | A rollout of 300,000 electricity meters or more needs a program review of deliveries, spares and field staffing. |
| 25 | The quote has 50,000 meters; the data concentrators serve 40,000 meters at 1,000 per concentrator in this model. |
| 26 | The quote states 50,000 meter points for the head-end, but the electricity and gas meters on it make 51,000. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a smart metering rollout of 80,000 Sagemcom T211 three-phase meters rated at 80 A on G3-PLC in the CENELEC A band with 70 data concentrators, collecting 30,000 gas meters over M-Bus, with DLMS Security Suite 0 and the remote disconnect relay, the Siconia head-end system, and 5 years of support. The quote states 80,000 meter points for the head-end. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a smart metering rollout of 80,000 Sagemcom XT211 three-phase meters rated at 80 A on G3-PLC in the CENELEC A band with 80 data concentrators, collecting 30,000 gas meters over M-Bus, with DLMS Security Suite 1 and the remote disconnect relay, the Siconia head-end system, and 5 years of support. The quote states 110,000 meter points for the head-end. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a smart metering rollout of 120,000 Sagemcom S211 single-phase meters rated at 100 A on NB-IoT with 120 data concentrators, with DLMS Security Suite 1, the utility's own head-end and the Siconia MDMS, and 5 years of support. The quote states 120,000 meter points for the head-end. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a smart metering rollout of 120,000 Sagemcom S211 single-phase meters rated at 80 A on NB-IoT, reporting straight to the head-end, with DLMS Security Suite 1, the utility's own head-end and the Siconia MDMS, and 5 years of support. The quote states 120,000 meter points for the head-end. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a smart metering rollout of 120,000 Sagemcom S211 single-phase meters rated at 80 A on NB-IoT, reporting straight to the head-end, with DLMS Security Suite 1, the Siconia head-end system and the Siconia MDMS, and 5 years of support. The quote states 120,000 meter points for the head-end. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a smart metering rollout of 40,000 Sagemcom XT211 three-phase meters rated at 80 A on PRIME in the FCC band with 35 data concentrators, with DLMS Security Suite 1, the Siconia head-end system, and 12 years of support. The quote states 40,000 meter points for the head-end. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a smart metering rollout of 40,000 Sagemcom XT211 three-phase meters rated at 80 A on PRIME in the CENELEC A band with 40 data concentrators, with DLMS Security Suite 1, the Siconia head-end system, and 10 years of support. The quote states 40,000 meter points for the head-end. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.