Predictika · Defibrillator and monitor quotes
An AI sales agent prepares a quote for SCHILLER DEFIGARD Touch 7 defibrillator/monitors: monitoring options, CPR feedback, electrodes, connectivity, mounting bracket, spare batteries and fleet size. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of how those choices fit together and returns a verdict and every reason.
This validator models SCHILLER DEFIGARD Touch 7 quotes, not just the scenarios shown below.
Any SCHILLER DEFIGARD Touch 7 quote that touches these rules is in scope — not only the scenarios pictured here. Not covered: other SCHILLER products (FRED, Cardiovit, Argus) and service contracts. No prices are modeled.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Options that depend on another option | Only with care SpCO and SpMet need Rainbow SpO2, SentioWeb and LifeDataNet need Wi-Fi or cellular, and the app, ePCR and printer need Bluetooth, so each dependency is its own rule that reads another choice. | Every option is in one request and the dependencies are checked together on every call. |
| Electrodes that limit what else can be ordered | Only with care The CPR feedback sensor depends on which electrodes are quoted, and an order with no electrodes has to be caught too, so each needs a rule that reads the electrode choice. | The electrodes and the CPR feedback option are fields of one request and are checked together. |
| A use environment that changes what is required | Only with workarounds Ambulance and air rescue use need the bracket, and wireless links on an air unit need a person, so the environment has to be read by several separate rules. | The environment is a field of the request, so the bracket rule and the approval rule are evaluated in the same pass. |
| A stated option count that must match the selected options | Only with workarounds The count is built from many yes-or-no choices and the EtCO2 setting, so a separate rule is needed to add them up and compare the sum with the stated figure. | The stated count is a field of the request and is compared with the computed count on every call. |
| Blocks and approvals in the same answer | Only with workarounds A fleet over 20 or a wireless link on an aircraft needs a person while other problems stop the quote, and these usually live in different steps. | Blocks and approvals come back together, with the reason for each. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 0 devices; at least 1 is needed. |
| 2 | The quote has 21 devices; a fleet of more than 20 needs a sales review. |
| 3 | The quote has no defibrillation electrodes; a defibrillator/monitor cannot be used without them. |
| 4 | SpCO and SpMet measurements need the Masimo Rainbow SpO2 option; it is not on the quote. |
| 5 | The ARGUS LifePoint 2 CPR feedback sensor is quoted with pediatric electrodes only; add adult electrodes. |
| 6 | SentioWeb live-streaming needs Wi-Fi or a cellular connection; neither is on the quote. |
| 7 | LifeDataNet G2 network management needs Wi-Fi or a cellular connection; neither is on the quote. |
| 8 | The Mirroring Screen App, the ePCR connection and the Bluetooth printer need Bluetooth; it is not on the quote. |
| 9 | Ambulance and air rescue use needs the mounting bracket (it also charges the battery); it is not on the quote. |
| 10 | Wireless links on an air rescue unit; a person should confirm the aircraft operator allows them. |
| 11 | The quote has 5 spare batteries per device; this model allows at most 4. |
| 12 | The brochure notes some products are not cleared in all markets; a person should confirm clearance for this configuration. |
| 13 | The quote states 6 options per device; the selected options add up to 4. |
| 14 | 8 options per device and no spare battery; a person should confirm the run time is acceptable. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 2 SCHILLER DEFIGARD Touch 7 units for a ground ambulance service, with adult and pediatric electrodes, 12-lead ECG, the pacer, SpCO, NIBP and sidestream EtCO2. Connectivity: Bluetooth and SentioWeb. The mounting bracket is not included and each unit has 1 spare battery. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 SCHILLER DEFIGARD Touch 7 units for a ground ambulance service, with adult and pediatric electrodes, 12-lead ECG, the pacer, Masimo Rainbow SpO2, SpCO, NIBP and sidestream EtCO2. Connectivity: cellular, Bluetooth and SentioWeb. The mounting bracket is included and each unit has 1 spare battery. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 2 SCHILLER DEFIGARD Touch 7 units for an air rescue service, with pediatric electrodes only, 12-lead ECG, the pacer, NIBP, ARGUS LifePoint 2 CPR feedback and sidestream EtCO2. Connectivity: Wi-Fi and Bluetooth. The mounting bracket is not included and each unit has 1 spare battery. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 2 SCHILLER DEFIGARD Touch 7 units for an air rescue service, with adult and pediatric electrodes, 12-lead ECG, the pacer, NIBP, ARGUS LifePoint 2 CPR feedback and sidestream EtCO2. Connectivity: Wi-Fi and Bluetooth. The mounting bracket is included and each unit has 1 spare battery. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 2 SCHILLER DEFIGARD Touch 7 units for an air rescue service, with adult and pediatric electrodes, 12-lead ECG, the pacer, NIBP, ARGUS LifePoint 2 CPR feedback and sidestream EtCO2. No connectivity is quoted. The mounting bracket is included and each unit has 1 spare battery. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 40 SCHILLER DEFIGARD Touch 7 units for a hospital, with adult and pediatric electrodes, 12-lead ECG, the pacer, NIBP and sidestream EtCO2. Connectivity: Wi-Fi and Bluetooth. The mounting bracket is not included and each unit has 1 spare battery. The quote lists 9 options per device. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 SCHILLER DEFIGARD Touch 7 units for a hospital, with adult and pediatric electrodes, 12-lead ECG, the pacer, NIBP and sidestream EtCO2. Connectivity: Wi-Fi and Bluetooth. The mounting bracket is not included and each unit has 1 spare battery. The quote lists 4 options per device. It is ready to send.
Verdict: Needs approval.
The text of the narrated walkthrough, step by step.