Predictika · Aluminium window system orders
An AI sales agent prepares an order of aluminium windows for a fabricator: which window series, the opening type, the fittings, the burglar resistance class, how the window is used and the thermal and sound figures the customer asks for. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published Schuco AWS series overview and returns a verdict, every reason and the figures it computed.
This validator models an order of Schuco aluminium windows from the 12 series in the published Schuco AWS overview table, not just the scenarios shown below.
Any order of these 12 series that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the Schuco documents read list none, so this page shows no price build-up), other Schuco systems (doors, facades, sliding systems, the AWS 75 PD.SI and AWS 90 variants not in the overview), glass, sizes and weights, finishes, and fabrication or installation.
8 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Features that exist only for some series | Only with workarounds Each of 12 series has its own set of opening types, fittings, security classes and uses. A rules-based CPQ needs a table or a rule per series and every catalog update means editing them. | The series and the options arrive in one request and are compared with that series' listed features on every call. |
| Limits that depend on two choices together | Only with care Security class depends on the fitting and the series together (for example RC3 is listed for AvanTec fittings only), so a rule must read three fields at once. | Series, fitting and class are checked together on every call. |
| Targets the series cannot reach | Only with care A required Uf or sound insulation is a free-entry figure; a rule can compare it with the series value only if that value is looked up first. | The series figures are computed and compared with the target on every call. |
| Options that need a person to confirm | Only with care Combinations the table does not list need a human decision, and a rules engine must route them by hand. | Unlisted combinations come back as a needs-approval finding that names the question for Schuco. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Burglar resistance class RC3 (WK3) is listed for AvanTec fittings only; TipTronic is listed up to RC2 (WK2). |
| 2 | A required Uf of 0.9 W/(m²K) is lower than the best Uf of 0.92 W/(m²K) listed for the chosen series. |
| 3 | A required sound insulation of 49 dB is more than the 48 dB listed for the chosen series. |
| 4 | Suitability for passive houses is listed only for AWS 90 BS.SI+ and AWS 90.SI+. |
| 5 | The order states a basic depth of 90 mm; the chosen series has 75 mm. |
| 6 | Group control, bus automation and automatic night-time cooling are listed under TipTronic automation for the AWS 90, AWS 75 and AWS 65 series only. |
| 7 | The Schüco overview lists TipTronic automation for turn/tilt, toplight and outward-opening vents only; a person should confirm TipTronic for a double vent or tilt/slide vent with Schüco. |
| 8 | Use as a floating window is listed only for AWS 75 BS.SI, AWS 75 BS.HI, AWS 65 BS and AWS 60 BS. |
| 9 | The Multi Contour (MC) design option is listed only for AWS 65, AWS 60 and AWS 60.HI. |
| 10 | Burglar resistance class RC3 (WK3) with AvanTec fittings is listed only for AWS 90 BS.SI+, AWS 90.SI+, AWS 75 .SI, AWS 75 BS.HI, AWS 65 and AWS 65 BS. |
| 11 | An outward-opening vent is listed only for AWS 75 .SI, AWS 75 BS.HI, AWS 65 WF, AWS 60 and AWS 60.HI. |
| 12 | Use as a facade insert unit is not listed for AWS 75 WF.SI or AWS 65 WF (they are window-facade series). |
| 13 | A required sound insulation of 46 dB is more than the 45 dB listed for the chosen series. |
| 14 | A double vent is not listed for the chosen series (listed for AWS 90, AWS 75 .SI, AWS 75 BS.SI, AWS 75 BS.HI, AWS 65, AWS 65 BS and the AWS 60 series, but not AWS 75 WF.SI or AWS 65 WF). |
| 15 | A required Uf of 1.3 W/(m²K) is lower than the best Uf of 1.4 W/(m²K) listed for the chosen series. |
| 16 | A tilt/slide vent is not listed for the chosen series (not listed for AWS 75 WF.SI or AWS 65 BS). |
| 17 | TipTronic with RC2 (WK2) is listed only for AWS 90, AWS 75 and AWS 65 (not AWS 65 BS, AWS 65 WF or the AWS 60 series). |
| 18 | Burglar resistance class RC2 (WK2) with AvanTec fittings is not listed for the chosen series (AWS 65 WF). |
| 19 | TipTronic with WK1 is listed only for the AWS 90, 75 and 65 series (not the AWS 60 series). |
| 20 | The Residential Line (RL) and Soft Line (SL) design options are listed only for AWS 75 .SI, AWS 65 and AWS 60. |
| 21 | Schüco TipTronic fittings are not listed for the AWS 60 BS series. |
| 22 | A side-hung, top-hung vent is listed only for AWS 75 .SI, AWS 75 BS.HI, AWS 60 and AWS 60.HI. |
| 23 | The order needs at least 1 window; it has 0. |
| 24 | TipTronic automation of an outward-opening vent is listed only for AWS 75 .SI and AWS 65. |
| 25 | Use as a window facade is listed only for AWS 75 WF.SI and AWS 65 WF. |
| 26 | A required Uf of 1.0 W/(m²K) is lower than the best Uf of 2.1 W/(m²K) listed for the chosen series. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please place an order of Schüco AWS 65 WF aluminium windows for Harbourline Fabrication, for 18 windows, turn/tilt, with AvanTec fittings, burglar resistance class RC2, for a window facade. The order states a basic depth of 65 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please place an order of Schüco AWS 65 WF aluminium windows for Harbourline Fabrication, for 18 windows, turn/tilt, with AvanTec fittings, burglar resistance class WK1, for a window facade. The order states a basic depth of 65 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please place an order of Schüco AWS 60 BS aluminium windows for Northfield Glazing, for 30 windows, turn/tilt, with TipTronic fittings, for facade insert units, with a required Uf of 1.7 W/(m²K) or better. The order states a basic depth of 60 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please place an order of Schüco AWS 60 BS aluminium windows for Northfield Glazing, for 30 windows, turn/tilt, with AvanTec fittings, for facade insert units, with a required Uf of 1.7 W/(m²K) or better. The order states a basic depth of 60 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please place an order of Schüco AWS 60.HI aluminium windows for Northfield Glazing, for 30 windows, turn/tilt, with AvanTec fittings, for facade insert units, with a required Uf of 1.7 W/(m²K) or better. The order states a basic depth of 60 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please place an order of Schüco AWS 75 BS.SI aluminium windows for Alderbrook Facades, for 12 windows, turn/tilt, with AvanTec fittings, burglar resistance class RC3, for floating windows, with a required Uf of 1.3 W/(m²K) or better, and sound insulation of at least 49 dB. The order states a basic depth of 75 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please place an order of Schüco AWS 75 BS.HI aluminium windows for Alderbrook Facades, for 12 windows, turn/tilt, with AvanTec fittings, burglar resistance class RC3, for floating windows, with a required Uf of 1.3 W/(m²K) or better, and sound insulation of at least 49 dB. The order states a basic depth of 75 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please place an order of Schüco AWS 75 BS.HI aluminium windows for Alderbrook Facades, for 12 windows, turn/tilt, with AvanTec fittings, burglar resistance class RC3, for floating windows, with a required Uf of 1.4 W/(m²K) or better, and sound insulation of at least 49 dB. The order states a basic depth of 75 mm. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.