Predictika · Humidity and temperature sensor orders

An AI sales agent's humidity sensor order, checked before it goes out

An AI sales agent prepares an order for a digital humidity and temperature sensor: accuracy class, I2C address, cover, reel size and quantity, plus how it will be powered and wired. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the ordering table and electrical limits in the public datasheet and returns a verdict, every reason and the figures it computed.

Scope: Sensirion SHT4x humidity and temperature sensors (SHT40, SHT41, SHT43, SHT45): orderable part, reel quantity, supply and operating limits. See everything this validator covers

This validator models orders for the Sensirion SHT4x family only (SHT40, SHT41, SHT43 and SHT45), not just the scenarios shown below. It does not cover any other Sensirion sensor.

  • Orderable parts — the combination of accuracy class, I2C address (0x44, 0x45, 0x46), cover (blank, polyimide membrane, removable protective cover) and reel size (2,500 or 10,000 pieces) must be one of the 18 parts in the datasheet ordering table.
  • Quantity and certificate — the reels must hold the sensors needed; the ISO17025 3-point calibration certificate comes only with the SHT43; the typical humidity accuracy the proposal states must match the datasheet for the family.
  • Electrical and operating limits — supply voltage 1.08 to 3.6 V, I2C pull-up resistors of at least 820 ohm below 1.62 V and 390 ohm above, application temperature within -40 to 125 degrees C, and a heater setting (20, 110 or 200 mW) whose maximum current fits the supply budget.

Any SHT4x order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the datasheet gives none, so this validator produces no price build-up or line-item quote), the SCD, SHT3x, SHT85 and other Sensirion families, the recommended 5 to 60 degrees C and 20 to 80 %RH operating band (only the absolute limits are checked), bus capacitance and timing, and packaging beyond the reel sizes.

The AI sales agentBuilds the sensor order from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Only 18 combinations of accuracy class, address, cover and reel existOnly with workarounds
The valid combinations are a table, not a pattern: some addresses exist only for some classes, and some covers only on the small reel. A rules-based CPQ needs the table loaded as rules or lookup data, and every new part number means editing it.
The ordering table is part of the model; any combination outside it is reported in one finding, whichever choice was changed.
A certificate that only one family comes withOnly with care
A product rule can tie the certificate to the SHT43, but it is another rule to write and keep in step with the catalog.
The certificate request and the family are checked together on every call.
Reels that must cover the units neededOnly with care
The reel size changes with the part, so the quantity check needs the size looked up first.
Reel capacity is computed on every call and compared with the units needed, including the exact boundary.
Supply, pull-up and heater limits that depend on each otherOnly with workarounds
The pull-up minimum depends on the supply voltage and the heater current on the heater setting, so each is a calculated threshold, not a simple range.
The thresholds are computed from the choices and checked together, with the boundaries tested.
A stated accuracy that must match the datasheetOnly with care
The stated figure is a free-entry field; a rule can compare it with the family value, but someone has to write and maintain that comparison.
The stated figure travels with the order and is compared with the family value on every call.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1The ordering table lists no SHT4x part with this accuracy class, I2C address, cover and reel size.
29,000 sensors are needed, but the reels on the order hold only 7,500.
3Only the SHT43 comes with the ISO17025 3-point calibration certificate; the selected family does not.
4The supply voltage of 1,000 mV is outside the 1,080 to 3,600 mV supply range of the SHT4x.
5The supply voltage of 3,700 mV is outside the 1,080 to 3,600 mV supply range of the SHT4x.
6The I2C pull-up resistors are 300 ohm, below the 390 ohm minimum for this supply voltage.
7The I2C pull-up resistors are 600 ohm, below the 820 ohm minimum for this supply voltage.
8The application temperature range of -50 to 60 degrees C is outside the -40 to 125 degrees C operating range of the SHT4x.
9The application temperature range of 0 to 130 degrees C is outside the -40 to 125 degrees C operating range of the SHT4x.
10The selected heater setting draws up to 100 mA, but the supply budget on the board is 50 mA.
11The selected heater setting draws up to 55 mA, but the supply budget on the board is 54 mA.
12The proposal states a typical humidity accuracy of 1.0 %RH, but the datasheet gives 1.8 %RH for this family.
13The proposal states a typical humidity accuracy of 1.8 %RH, but the datasheet gives 1.0 %RH for this family.
149,000 sensors are needed, but the reels on the order hold only 5,000.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Thermostat build: An SHT45 ordered with the 0x45 address

The agent's request. Please order 1 x 10,000-piece reel of the SHT45 with I2C address 0x45 and a blank package, for a design that needs 9,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the heater off, in an application from 0 to 60 degrees C, with no certificate. The order states a typical humidity accuracy of 1.0 %RH. It is ready to send.

Verdict: Blocked.

  • Not an orderable part. The ordering table lists no SHT4x part with this accuracy class, I2C address, cover and reel size.

2. Thermostat build: The agent resubmits after fixing the errors

The agent's request. Please order 1 x 10,000-piece reel of the SHT45 with I2C address 0x44 and a blank package, for a design that needs 9,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the heater off, in an application from 0 to 60 degrees C, with no certificate. The order states a typical humidity accuracy of 1.0 %RH. It is ready to send.

Verdict: Allowed.

  • Order summary. 9,000 sensors needed; the reels hold 10,000; typical humidity accuracy 1.0 %RH.

3. Outdoor logger: An outdoor logger order with too few reels, a -50 degree minimum and a 200 mW heater

The agent's request. Please order 2 x 2,500-piece reels of the SHT41 with I2C address 0x44 and the removable protective cover, for a design that needs 6,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the 200 mW heater setting, in an application from -50 to 70 degrees C, with no certificate. The order states a typical humidity accuracy of 1.8 %RH. It is ready to send.

Verdict: Blocked.

  • Reels do not cover the units needed. 6,000 sensors are needed, but the reels on the order hold only 5,000.
  • Application temperature outside the sensor range. The application temperature range of -50 to 70 degrees C is outside the -40 to 125 degrees C operating range of the SHT4x.
  • Heater draws more than the supply budget. The selected heater setting draws up to 100 mA, but the supply budget on the board is 50 mA.

4. Outdoor logger: The agent resubmits after fixing the errors

The agent's request. Please order 3 x 2,500-piece reels of the SHT41 with I2C address 0x44 and the removable protective cover, for a design that needs 6,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the 200 mW heater setting, in an application from -40 to 70 degrees C, with no certificate. The order states a typical humidity accuracy of 1.8 %RH. It is ready to send.

Verdict: Blocked.

  • Heater draws more than the supply budget. The selected heater setting draws up to 100 mA, but the supply budget on the board is 50 mA.

5. Outdoor logger: The agent resubmits after fixing the errors

The agent's request. Please order 3 x 2,500-piece reels of the SHT41 with I2C address 0x44 and the removable protective cover, for a design that needs 6,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the 20 mW heater setting, in an application from -40 to 70 degrees C, with no certificate. The order states a typical humidity accuracy of 1.8 %RH. It is ready to send.

Verdict: Allowed.

  • Order summary. 6,000 sensors needed; the reels hold 7,500; typical humidity accuracy 1.8 %RH.

6. Lab logger: A certified lab logger ordered on an SHT45

The agent's request. Please order 2 x 2,500-piece reels of the SHT45 with I2C address 0x44 and a blank package, for a design that needs 5,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the heater off, in an application from 0 to 60 degrees C, with the ISO17025 calibration certificate. The order states a typical humidity accuracy of 1.0 %RH. It is ready to send.

Verdict: Blocked.

  • ISO17025 certificate only on the SHT43. Only the SHT43 comes with the ISO17025 3-point calibration certificate; the selected family does not.

7. Lab logger: The agent resubmits after fixing the errors

The agent's request. Please order 1 x 10,000-piece reel of the SHT43 with I2C address 0x44 and a blank package, for a design that needs 5,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the heater off, in an application from 0 to 60 degrees C, with the ISO17025 calibration certificate. The order states a typical humidity accuracy of 1.8 %RH. It is ready to send.

Verdict: Allowed.

  • Order summary. 5,000 sensors needed; the reels hold 10,000; typical humidity accuracy 1.8 %RH.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares an order for a digital humidity and temperature sensor: accuracy class, I2C address, cover, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the ordering table and electrical limits in the public datasheet and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please order 2 x 2,500-piece reels of the SHT41 with I2C address 0x44 and the removable protective cover, for a design that needs 6,000 sensors. The board runs at 3,300 mV with 4,700 ohm pull-ups, a 50 mA supply budget and the 200 mW heater setting. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. 6,000 sensors are needed, but the reels on the order hold only 5,000. The application temperature range of -50 to 70 degrees C is outside the -40 to 125 degrees C operating range of the SHT4x. The selected heater setting draws up to 100 mA, but the supply budget on the board is 50 mA.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for reels that must cover the units needed, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the reels to 3 and the application temperature to -40 to 70.
  10. It calls the validator again.
  11. Still blocked, with one finding, all in one answer. The selected heater setting draws up to 100 mA, but the supply budget on the board is 50 mA.
  12. Two findings cleared. Still blocking: heater draws more than the supply budget.
  13. The agent resubmits once more.
  14. The revised request. It changes the heater to 20 mw heater setting.
  15. It calls the validator once more.
  16. This time the validator clears it.
  17. The earlier finding is cleared, and the validator's figure matches the quote.
  18. Three problems caught in one call, fixed in two passes, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer. Now you can try the other scenarios yourself.