Predictika · Metal stud partition wall systems
An AI sales agent prepares an order for a metal stud partition wall from a public system catalogue, with a fire requirement, a sound requirement and a wall height. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published system data and returns a verdict, every reason and the figures it computed.
This validator models orders for seven Siniat single frame metal stud partition systems whose public system data pages were read, not just the scenarios shown below.
Any order for these systems that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the system pages list none, so this validator produces no price build-up or line-item quote), the rest of the Siniat range (twin frame, shaft wall, ceilings, linings and timber stud systems), board quantities and other site conditions. Note: the maximum heights and ratings are the figures on the data pages read; a project must confirm them against the current manufacturer documents.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A fire requirement that the system cannot meet | Only with care Each system has its own rating, so each needs its own comparison, and every new system adds more rules to maintain. | The system and the requirement are in one request and compared on every call. |
| A maximum height that is lower in the fire state | Only with workarounds The height limit depends on both the system and whether a fire rating is required, so it needs a cross-field rule per system that interacts with the others. | The system, the height and the fire requirement travel together and every limit is checked at once. |
| Tiled finishes that need closer stud centres | Only with care A condition that applies to some systems only, kept as a product rule per system and maintained by hand. | The tiled flag, the stud centres and the system are checked together on every call. |
| A stated thickness that disagrees with the system | Only with workarounds The figure the agent states is free text or a separate field, so it takes an extra rule that compares it with the system's own thickness. | The stated figure is part of the request and is compared with the system's thickness on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The wall must resist fire for 60 minutes; the selected system is rated for 30 minutes (EI). |
| 2 | The wall must give 55 dB of sound insulation (Rw); the selected system gives 50 dB. |
| 3 | The wall is 4,700 mm high; the selected system allows a maximum of 4,600 mm. |
| 4 | The wall is 5,100 mm high; with a fire requirement the selected system allows a maximum of 5,000 mm in the fire state. |
| 5 | The wall is 5,300 mm high; the selected system allows a maximum of 5,250 mm. |
| 6 | The wall is 6,000 mm high; with a fire requirement the selected system allows a maximum of 5,000 mm in the fire state. |
| 7 | The wall is 7,400 mm high; the selected system allows a maximum of 7,350 mm. |
| 8 | The wall is 7,400 mm high; with a fire requirement the selected system allows a maximum of 7,350 mm in the fire state. |
| 9 | The wall must resist fire for 90 minutes; the selected system is rated for 60 minutes (EI). |
| 10 | The wall is to be tiled; this system needs studs at 400 mm centres if tiled, but the quote has 600 mm. |
| 11 | The wall is to be tiled; the system data read for this system does not state tiling stud centres, so a person should confirm them with the manufacturer. |
| 12 | Stud centres of 450 mm are not listed; the system data gives 600 mm centres, or 400 mm if the wall is to be tiled. |
| 13 | The quote states a wall thickness of 120 mm, but the selected system is 130 mm (nominal). |
| 14 | The quote states a wall thickness of 0 mm, but the selected system is 130 mm (nominal). |
| 15 | The wall is 3,100 mm high; the selected system allows a maximum of 3,000 mm. |
| 16 | The wall is 3,100 mm high; with a fire requirement the selected system allows a maximum of 3,000 mm in the fire state. |
| 17 | The wall is 3,600 mm high; the selected system allows a maximum of 3,500 mm. |
| 18 | The wall is 3,600 mm high; with a fire requirement the selected system allows a maximum of 3,500 mm in the fire state. |
| 19 | The wall must give 50 dB of sound insulation (Rw); the selected system gives 44 dB. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Siniat CS50R-15dB-25G single frame partition wall, 3,200 mm high, that must give 60 minutes of fire resistance and 55 dB of sound insulation, with studs at 600 mm centres and a stated wall thickness of 80 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Siniat CS70R-15Un-50G single frame partition wall, 3,200 mm high, that must give 60 minutes of fire resistance and 55 dB of sound insulation, with studs at 600 mm centres and a stated wall thickness of 100 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Siniat CS70R-212dB-FFG single frame partition wall, 3,200 mm high, that must give 60 minutes of fire resistance and 55 dB of sound insulation, with studs at 600 mm centres and a stated wall thickness of 120 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Siniat CS70R-215dB-25G single frame partition wall, 5,100 mm high, that must give 60 minutes of fire resistance and 50 dB of sound insulation, with studs at 600 mm centres and a stated wall thickness of 130 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Siniat CS14R-15Md-25G single frame partition wall, 5,100 mm high, that must give 60 minutes of fire resistance and 50 dB of sound insulation, with studs at 600 mm centres and a stated wall thickness of 176 mm. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Siniat CS70R-215dB-25G single frame partition wall, 4,800 mm high, that must give 60 minutes of fire resistance and 50 dB of sound insulation, to be tiled, with studs at 600 mm centres and a stated wall thickness of 130 mm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Siniat CS70R-215dB-25G single frame partition wall, 4,800 mm high, that must give 60 minutes of fire resistance and 50 dB of sound insulation, to be tiled, with studs at 400 mm centres and a stated wall thickness of 130 mm. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.