An AI sales agent prepares an order for a SolarEdge three-phase commercial inverter (USA Domestic Content Eligible, SE10KUS to SE40KUS) for a fictional commercial rooftop solar installer: the model, the grid voltage at the site, the DC array and its voltage and current, the wiring and any domestic content requirement. Before the order goes out, the agent sends it to Predictika, which checks it against a declarative model of what the public SolarEdge datasheet says and returns a verdict, every reason and the figures it computed. The customer is fictional.

Scope: SolarEdge SE10KUS, SE17.3KUS, SE30KUS and SE40KUS three-phase commercial inverters only: grid, DC array, voltage, current, wiring, site, noise, power factor and options. See everything this validator covers

This validator models orders for the SolarEdge three-phase commercial inverters SE10KUS, SE17.3KUS, SE30KUS and SE40KUS (USA Domestic Content Eligible), based on the public datasheet DS-000246-NAM of January 2025, not just the scenarios shown below.

  • Grid — the line-to-line voltage range of each model (183 to 229 V for the SE10KUS and SE17.3KUS, 422.5 to 529 V for the SE30KUS and SE40KUS) and a 60 Hz grid; the power factor range of 0.85 to 1.
  • DC array — maximum DC power, operating voltage range, maximum input current, maximum short circuit current of 55 A and 3 fuseless DC input pairs.
  • AC output and statement — the AC power the project needs against the rated output, and the rated output the order states against the datasheet.
  • Wiring and site — AC wire 6 to 10 AWG, DC wire 6 to 12 AWG, an operating range of -40 to 140 F and a noise level below 62 dBA against the site limit.
  • Options — domestic content eligibility (only with certain SolarEdge USA-manufactured power optimizers; a person confirms the pairing and the tax treatment) and the built-in rapid shutdown, listed when paired with the C651U.

Any order of these four inverters that touches these rules is in scope — not only the scenarios pictured here. Not covered: power optimizer string sizing (the datasheet refers to a separate technical note), temperature derating, other SolarEdge inverters, prices (SolarEdge does not publish them), delivery and installation.

The AI sales agentBuilds the inverter order from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

8 scenarios in 4 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
Limits that differ by modelOnly with care
The voltage class, DC power, operating voltage and input current all differ between the four models. A rules-based CPQ can store the table, but it has to be kept in step and compared with each design.
The model is read together with the grid and the DC design, and every limit is computed on every call.
Options that depend on a pairingOnly with care
Domestic content eligibility depends on pairing the inverter with certain USA-manufactured optimizers. Each is a product rule that has to be written and maintained.
The pairing is checked together with the requirement on every call.
The figure the order statesOnly with care
The rated output stated in the order is a free-entry field; a rule has to look up the right table row and compare.
The stated figure is a field in the request, compared with the datasheet figure for the model on every call.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1The site voltage is 208.0 V line to line; the datasheet gives 422.5 to 529.0 V for this model.
2The site voltage is 480.0 V line to line; the datasheet gives 183.0 to 229.0 V for this model.
3The site voltage is 422.4 V line to line; the datasheet gives 422.5 to 529.0 V for this model.
4The site voltage is 529.1 V line to line; the datasheet gives 422.5 to 529.0 V for this model.
5The site voltage is 182.9 V line to line; the datasheet gives 183.0 to 229.0 V for this model.
6The site voltage is 229.1 V line to line; the datasheet gives 183.0 to 229.0 V for this model.
7The datasheet gives a 60 Hz grid (59.3 to 60.5 Hz); the site is 50 Hz.
8The datasheet gives a 60 Hz grid (59.3 to 60.5 Hz); the site is 59 Hz.
9The array is 52501 W DC; the datasheet gives a maximum DC power of 52500 W for this model.
10The array is 17501 W DC; the datasheet gives a maximum DC power of 17500 W for this model.
11The design DC voltage is 839 V; the datasheet gives an operating range of 840 to 1000 V for this model.
12The design DC voltage is 1001 V; the datasheet gives an operating range of 840 to 1000 V for this model.
13The design DC voltage is 369 V; the datasheet gives an operating range of 370 to 600 V for this model.
14The design DC voltage is 601 V; the datasheet gives an operating range of 370 to 600 V for this model.
15The design DC current is 36.3 A; the datasheet gives a maximum input current of 36.25 A for this model.
16The design DC current is 27.9 A; the datasheet gives a maximum input current of 27.8 A for this model.
17The design DC current is 48.3 A; the datasheet gives a maximum input current of 48.25 A for this model.
18The design short circuit current is 55.1 A; the datasheet gives a maximum input short circuit current of 55 A.
19The design has 4 DC input pairs; the datasheet gives 3 fuseless DC input pairs.
20The project needs 30001 W of AC output; this model is rated 30000 W.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Model and grid voltage: SE30KUS on a 208 V site

The agent's request. Please quote a SolarEdge SE30KUS for a 208 V site at 60 Hz. The project needs 15,000 W of AC output, with a 24,000 W DC array at a design of 450 V, 40 A and a short circuit current of 45 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 30,000 W. It is ready to send.

Verdict: Blocked.

  • Grid voltage outside the inverter range. The site voltage is 208.0 V line to line; the datasheet gives 422.5 to 529.0 V for this model.
  • DC voltage outside the operating range. The design DC voltage is 450 V; the datasheet gives an operating range of 840 to 1000 V for this model.
  • DC current above the maximum input current. The design DC current is 40.0 A; the datasheet gives a maximum input current of 36.25 A for this model.

2. Model and grid voltage: The agent resubmits after fixing the errors

The agent's request. Please quote a SolarEdge SE17.3KUS for a 208 V site at 60 Hz. The project needs 15,000 W of AC output, with a 24,000 W DC array at a design of 450 V, 40 A and a short circuit current of 45 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 17,300 W. It is ready to send.

Verdict: Allowed.

  • Order summary. This inverter is rated 17300 W AC, accepts up to 30275 W of DC array power and works at 370 to 600 V DC.

3. DC array size: SE10KUS with a 20,000 W array

The agent's request. Please quote a SolarEdge SE10KUS for a 208 V site at 60 Hz. The project needs 9,000 W of AC output, with a 20,000 W DC array at a design of 450 V, 25 A and a short circuit current of 30 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 10,000 W. It is ready to send.

Verdict: Blocked.

  • DC array larger than the maximum DC power. The array is 20000 W DC; the datasheet gives a maximum DC power of 17500 W for this model.

4. DC array size: The agent resubmits after fixing the errors

The agent's request. Please quote a SolarEdge SE10KUS for a 208 V site at 60 Hz. The project needs 9,000 W of AC output, with a 17,000 W DC array at a design of 450 V, 25 A and a short circuit current of 30 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 10,000 W. It is ready to send.

Verdict: Allowed.

  • Order summary. This inverter is rated 10000 W AC, accepts up to 17500 W of DC array power and works at 370 to 600 V DC.

5. Domestic content: Domestic content without USA optimizers

The agent's request. Please quote a SolarEdge SE30KUS for a 480 V site at 60 Hz. The project needs 30,000 W of AC output, with a 45,000 W DC array at a design of 900 V, 30 A and a short circuit current of 40 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The project needs domestic content eligibility and the order has no USA-manufactured power optimizers. The quote states a rated output of 30,000 W. It is ready to send.

Verdict: Blocked.

  • Domestic content needs USA optimizers. The datasheet gives domestic content eligibility only when paired with certain SolarEdge USA-manufactured power optimizers; the order has none.

6. Domestic content: The agent resubmits after fixing the errors

The agent's request. Please quote a SolarEdge SE30KUS for a 480 V site at 60 Hz. The project needs 30,000 W of AC output, with a 45,000 W DC array at a design of 900 V, 30 A and a short circuit current of 40 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The project needs domestic content eligibility and the order has USA-manufactured SolarEdge power optimizers. The quote states a rated output of 30,000 W. It is ready to send.

Verdict: Needs approval.

  • Domestic content pairing to confirm. The datasheet gives domestic content eligibility for certain USA-manufactured optimizers only and gives no tax advice; a person should confirm the optimizer part numbers and the tax treatment.
  • Order summary. This inverter is rated 30000 W AC, accepts up to 52500 W of DC array power and works at 840 to 1000 V DC.

7. Wire gauge: SE30KUS with 4 AWG AC wire

The agent's request. Please quote a SolarEdge SE30KUS for a 480 V site at 60 Hz. The project needs 30,000 W of AC output, with a 45,000 W DC array at a design of 900 V, 30 A and a short circuit current of 40 A over 3 DC input pairs. The AC wire is 4 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 30,000 W. It is ready to send.

Verdict: Blocked.

  • AC wire gauge outside 6 to 10 AWG. The AC wire is 4 AWG; the datasheet gives an AC range of 6 to 10 AWG.

8. Wire gauge: The agent resubmits after fixing the errors

The agent's request. Please quote a SolarEdge SE30KUS for a 480 V site at 60 Hz. The project needs 30,000 W of AC output, with a 45,000 W DC array at a design of 900 V, 30 A and a short circuit current of 40 A over 3 DC input pairs. The AC wire is 8 AWG and the DC wire is 10 AWG, the site runs from 20 F to 110 F with a limit of 70 dBA, and the utility asks for a power factor of 95 percent. The quote states a rated output of 30,000 W. It is ready to send.

Verdict: Allowed.

  • Order summary. This inverter is rated 30000 W AC, accepts up to 52500 W of DC array power and works at 840 to 1000 V DC.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares an order for a SolarEdge three-phase commercial inverter (USA Domestic Content Eligible, SE10KUS to SE40KUS) for a fictional commercial rooftop solar installer: the model, the grid voltage at the site, the DC array and its voltage and current, and more. Before the order goes out, the agent sends it to Predictika, which checks it against a declarative model of what the public SolarEdge datasheet says and returns a verdict, every reason and the figures it computed. The customer is fictional.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote a SolarEdge SE30KUS for a 208 V site at 60 Hz. The project needs 15,000 W of AC output, with a 24,000 W DC array at a design of 450 V. The rest of the request is on screen. The quote states a rated output of 30,000 W.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. The site voltage is 208.0 V line to line; the datasheet gives 422.5 to 529.0 V for this model. The design DC voltage is 450 V; the datasheet gives an operating range of 840 to 1000 V for this model. The design DC current is 40.0 A; the datasheet gives a maximum input current of 36.25 A for this model.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for limits that differ by model, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the model to SE17.3KUS and the stated rated output to 17,300.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All three earlier findings are cleared, and the validator's figure matches the quote.
  13. Three problems caught in one call, fixed in one pass, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer. Now you can try the other scenarios yourself.