Predictika · Refrigerated merchandiser orders

An AI sales agent's Endless merchandiser order, checked before it goes out

An AI sales agent prepares an order for Master-Bilt Endless glass door merchandisers: cabinet modules, ends, the condensing unit, refrigerant and options. Before it goes out, the agent sends the order to Predictika, which checks it against a declarative model of the public Endless spec sheets and returns a verdict, every reason and the pack-out it computed.

Scope: Master-Bilt (Standex) Endless glass door merchandisers: BEM medium temperature and BEL low temperature, remote and semi-self-contained (-SC), in 2, 3, 4 and 5 door modules. See everything this validator covers

This validator models Endless merchandiser orders, not just the scenarios shown below.

  • Cabinets and line-ups — 2, 3, 4 and 5 door modules with 30 in doors, up to 25 doors, with cabinet ends ordered separately and partitions between semi-self-contained modules.
  • Condensing unit, phase and refrigerant — the condensing unit chart for remote line-ups from 2 to 15 doors (medium and low temperature classes), single and three phase, and the refrigerants offered on remote and semi-self-contained cabinets.
  • Options and stated figures — anti-fog film on low temperature doors, the extended compressor warranty, and the stated BTU/h and pack-out compared with the published figures.

Any Endless order that touches these rules is in scope — not only the scenarios pictured here. Not covered: walk-in coolers, other Master-Bilt lines, accessories, installation, and prices. The validator models no prices, so the page shows no price build-up.

The AI sales agentBuilds the merchandiser order from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
A condensing unit that must match the door countOnly with care
The unit chart changes with the total doors across all modules, so every module combination needs its own rule or a lookup table that someone must keep in step with the chart.
The module counts and the chosen unit are in one request, and the validator looks the required unit up from the total doors on every call.
Units that are only offered in one phaseOnly with care
Each unit needs its own phase rule, and the phase choice is usually made on a different step from the unit.
The phase and the unit are fields of the same request and are checked against each other on every call.
Options that apply to one temperature class or system typeOnly with care
Anti-fog film, extended warranty, refrigerant and a separate condensing unit each depend on the temperature class or on remote versus semi-self-contained, so each option needs its own conditional rule.
Temperature class, system type and every option are in one request and checked together.
A stated capacity or pack-out that must match the published figureOnly with workarounds
The figure is built from the modules and the door count, so a separate rule has to recompute it and compare it with the stated number.
The stated BTU/h and pack-out are fields of the request and are compared with the computed figures on every call.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as an option is picked or a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the order; approval findings need a person to sign off; everything else is computed.

1Each semi-self-contained module has its own condensing unit, so a partition is needed between modules; 0 ordered for 2 modules.
2The order has no cabinets; add at least one 2, 3, 4 or 5 door module.
3The condensing unit chart for remote line-ups stops at 15 doors; 25 doors need separate systems with partitions.
4The line-up is over 20 feet long; a person should confirm the store layout and delivery access.
526 doors is more than the published line-up tables cover (25 doors).
6Cabinet ends are ordered separately and the line-up needs a pair of ends.
7More than one pair of ends is ordered; a line-up normally takes one pair, so a person should confirm.
8A remote line-up needs a condensing unit; none is selected.
9The selected condensing unit is for the other temperature class.
10The selected condensing unit is smaller than the chart requires for 4 doors.
11The selected condensing unit is larger than the chart unit for this line-up; a person should confirm.
12Semi-self-contained cabinets include their condensing unit; do not order a separate one.
13The selected condensing unit is single-phase only.
14The selected condensing unit is three-phase only.
15Semi-self-contained cabinets are supplied single phase (208-230 V).
16Remote cabinets are supplied for R-448A or R-449A, not R-404A.
17Semi-self-contained cabinets are offered with R-404A or R-449A, not R-448A.
18Anti-fog film is offered on low temperature (BEL) glass doors only.
19The extended compressor warranty is for remote condensing units; semi-self-contained units already carry five-year compressor coverage.
20The order states 3,450 BTU/h; the published table gives 3,750 BTU/h for this line-up.
21The order states 100.6 cu ft of pack-out; the cabinets add up to 80.6 cu ft.
22Partitions are only needed when modules have their own condensing units; a person should confirm.
23The condensing unit chart for remote line-ups stops at 15 doors; 16 doors need separate systems with partitions.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Semi-self-contained cabinet options: A semi-self-contained 3-door medium temperature order with several options

The agent's request. Please quote an Endless BEM medium temperature merchandiser order, semi-self-contained (-SC), one 3-door module, condensing unit MHMD002EB, three phase, refrigerant R-448A, with anti-fog film and the extended compressor warranty, for 80.6 cu ft of pack-out. It is ready to send.

Verdict: Blocked.

  • Ends not ordered. Cabinet ends are ordered separately and the line-up needs a pair of ends.
  • Condensing unit on semi-self-contained. Semi-self-contained cabinets include their condensing unit; do not order a separate one.
  • Semi-self-contained is single phase. Semi-self-contained cabinets are supplied single phase (208-230 V).
  • Refrigerant not offered on semi-self-contained. Semi-self-contained cabinets are offered with R-404A or R-449A, not R-448A.
  • Anti-fog film on medium temp. Anti-fog film is offered on low temperature (BEL) glass doors only.
  • Extended warranty on semi-self-contained. The extended compressor warranty is for remote condensing units; semi-self-contained units already carry five-year compressor coverage.

2. Semi-self-contained cabinet options: The agent resubmits after fixing the errors

The agent's request. Please quote an Endless BEM medium temperature merchandiser order, semi-self-contained (-SC), one 3-door module, with 1 pair of ends, single phase, refrigerant R-449A, for 80.6 cu ft of pack-out. It is ready to send.

Verdict: Allowed.

  • Order summary. 3 doors in 1 module, pack-out 80.6 cu ft.

3. Low temperature remote line-up: A low temperature 7-door remote line-up with its condensing unit, refrigerant and capacity

The agent's request. Please quote an Endless BEL low temperature merchandiser order, remote, one 3-door module and one 4-door module, with 2 pairs of ends, condensing unit MSLD025E, three phase, refrigerant R-404A, for 9,800 BTU/h and 187.7 cu ft of pack-out. It is ready to send.

Verdict: Blocked.

  • Condensing unit too small. The selected condensing unit is smaller than the chart requires for 7 doors.
  • Refrigerant not offered on remote. Remote cabinets are supplied for R-448A or R-449A, not R-404A.
  • Stated capacity does not match. The order states 9,800 BTU/h; the published table gives 10,675 BTU/h for this line-up.
  • More than one pair of ends. More than one pair of ends is ordered; a line-up normally takes one pair, so a person should confirm.

4. Low temperature remote line-up: The agent resubmits after fixing the errors

The agent's request. Please quote an Endless BEL low temperature merchandiser order, remote, one 3-door module and one 4-door module, with 1 pair of ends, condensing unit MSLD035E, three phase, refrigerant R-449A, with anti-fog film, for 10,675 BTU/h and 187.7 cu ft of pack-out. It is ready to send.

Verdict: Allowed.

  • Order summary. 7 doors in 2 modules, pack-out 187.7 cu ft.

5. Medium temperature remote line-up: A medium temperature 7-door remote line-up with its condensing unit, film and partitions

The agent's request. Please quote an Endless BEM medium temperature merchandiser order, remote, one 3-door module and one 4-door module, with 1 pair of ends, condensing unit MSLD035E, single phase, refrigerant R-449A, 2 partitions, with anti-fog film, for 8,050 BTU/h and 190.0 cu ft of pack-out. It is ready to send.

Verdict: Blocked.

  • Condensing unit wrong temperature class. The selected condensing unit is for the other temperature class.
  • Anti-fog film on medium temp. Anti-fog film is offered on low temperature (BEL) glass doors only.
  • Stated pack-out does not match. The order states 190.0 cu ft of pack-out; the cabinets add up to 187.7 cu ft.
  • Partitions on a shared remote system. Partitions are only needed when modules have their own condensing units; a person should confirm.

6. Medium temperature remote line-up: The agent resubmits after fixing the errors

The agent's request. Please quote an Endless BEM medium temperature merchandiser order, remote, one 3-door module and one 4-door module, with 1 pair of ends, condensing unit MHMD008EB, single phase, refrigerant R-449A, with the extended compressor warranty, for 8,050 BTU/h and 187.7 cu ft of pack-out. It is ready to send.

Verdict: Allowed.

  • Order summary. 7 doors in 2 modules, pack-out 187.7 cu ft.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares an order for Master-Bilt Endless glass door merchandisers: cabinet modules, ends, the condensing unit, and more. Before it goes out, the agent sends the order to Predictika, which checks it against a declarative model of the public Endless spec sheets and returns a verdict, every reason and the pack-out it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote an Endless BEM medium temperature merchandiser order, semi-self-contained (-SC), one 3-door module, condensing unit MHMD002EB, three phase, refrigerant R-448A. It is ready to send. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with six findings, all in one answer. Cabinet ends are ordered separately and the line-up needs a pair of ends. Semi-self-contained cabinets include their condensing unit; do not order a separate one. Semi-self-contained cabinets are supplied single phase (208-230 V). The other three are on screen.
  6. The validator returned six blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the order are checked against each other.
  7. What this shows: for units that are only offered in one phase, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the pairs of ends to 1, the condensing unit to none, the phase to single and the refrigerant to R-449A. Two more changes are on screen.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All six earlier findings are cleared.