Predictika · Facade insulation systems
An AI sales agent prepares a quote for a StoTherm external thermal insulation composite system: which StoTherm system, how much insulation, what the wall is made of, how the boards are fixed, how much impact the facade must take, the finish and the shade. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the Sto StoTherm processing guideline and returns a verdict, every reason and the figures it computed.
This validator models the choice and build-up of one StoTherm system, based on the public Sto StoTherm-Systeme processing guideline (Verarbeitungsrichtlinie), not just the scenarios shown below.
Any StoTherm order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the guideline has none, so this page shows no price build-up), dowel counts and layouts, window and base profiles, building height and fire barrier requirements, national approvals, other Sto systems, and whether a system is the right choice for the building.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Insulation thickness limits that differ by system | Only with care Five systems with five maximum thicknesses, a lower limit when ceramic or stone cladding is used, and stated figures to compare, are easy to leave out of step with the guideline. | Each limit is checked on every call and the answer names both numbers. |
| Fixing method chosen from unevenness and wall strength | Only with workarounds Bonding, bonding with dowels and mechanical fixing each allow a different unevenness, and a weak wall rules out bonding alone, so the choice depends on several fields at once. | The fixing, the unevenness and the wall strength are checked together, and the Rotofix type follows from the gap. |
| Impact rating that depends on system and build | Only with workarounds Only two systems carry a joule figure, each with a standard and a high-impact build, so a requirement needs a lookup on both before it can be compared. | The rating for the system and build is looked up and compared with the requirement, and with any rating the quote states. |
| Light reflectance limits and their exceptions | Only with care Two limits depending on the system, darker shades on request, and a coating that allows lower values: a person has to remember which case applies. | Below-limit shades are blocked or sent to a person depending on the system and the coating. |
| Systems described for only some substrates, finishes and fixings | Only with care PIR has no mechanical fixing, stone cladding exists on two systems, and Classic S1 is solid-wall only: each exclusion is a separate rule on separate lines. | All of them are checked together, in any order the choices arrive. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | An insulation thickness of 401 mm is above the 400 mm the guideline gives for this system. |
| 2 | An insulation thickness of 301 mm is above the 300 mm the guideline gives for this system. |
| 3 | An insulation thickness of 350 mm is above the 300 mm the guideline gives for this system. |
| 4 | An insulation thickness of 450 mm is above the 400 mm the guideline gives for this system. |
| 5 | An insulation thickness of 201 mm is above the 200 mm the guideline gives for this system. |
| 6 | This system is described for solid masonry or concrete only; the substrate chosen is timber construction. |
| 7 | This system is described for solid masonry or concrete only; the substrate chosen is steel construction. |
| 8 | For a substrate of timber construction the guideline lists the system but gives its fixing figures for solid masonry and concrete only; a person should confirm the fixing against the technical approval. |
| 9 | For a substrate of an existing ETICS the guideline lists the system but gives its fixing figures for solid masonry and concrete only; a person should confirm the fixing against the technical approval. |
| 10 | For a substrate of steel construction the guideline lists the system but gives its fixing figures for solid masonry and concrete only; a person should confirm the fixing against the technical approval. |
| 11 | Ceramic or natural stone cladding is described only for StoTherm Mineral and StoTherm Vario. |
| 12 | With ceramic or natural stone cladding the guideline allows at most 200 mm of insulation; the order has 220 mm. |
| 13 | With ceramic or natural stone cladding the guideline allows at most 200 mm of insulation; the order has 300 mm. |
| 14 | A light reflectance value of 14 is below the general 15; the guideline says darker shades are possible on request or with X-black coatings but gives no lower limit, so Sto should confirm. |
| 15 | A light reflectance value of 10 is below the general 15; the guideline says darker shades are possible on request or with X-black coatings but gives no lower limit, so Sto should confirm. |
| 16 | A light reflectance value of 19 is below the 20 the guideline gives for the finish coat of this system. |
| 17 | A light reflectance value of 19 is below the general 20; the guideline says darker shades are possible on request or with X-black coatings but gives no lower limit, so Sto should confirm. |
| 18 | A light reflectance value of 10 is below the 20 the guideline gives for the finish coat of this system. |
| 19 | A light reflectance value of 10 is below the general 20; the guideline says darker shades are possible on request or with X-black coatings but gives no lower limit, so Sto should confirm. |
| 20 | A light reflectance value of 120 is outside the 0 to 100 scale. |
| 21 | A light reflectance value of -5 is outside the 0 to 100 scale. |
| 22 | An unevenness of 2 cm per meter is above the 1 cm per meter this fixing method allows. |
| 23 | An unevenness of 3 cm per meter is above the 2 cm per meter this fixing method allows. |
| 24 | An unevenness of 8 cm per meter is above the 7 cm per meter this fixing method allows. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote StoTherm PIR with 240 mm of insulation on a timber construction, with a pull-off strength below 0.08 newtons per square millimeter, mechanical fixing with Sto-Rotofix plus, for an unevenness of 4 cm per meter. The finish is render in a shade with a light reflectance value of 12. The quote says the system takes up to 240 mm of insulation. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote StoTherm Vario with 240 mm of insulation on solid masonry or concrete, with a pull-off strength below 0.08 newtons per square millimeter, mechanical fixing with Sto-Rotofix plus, for an unevenness of 4 cm per meter. The finish is render in a shade with a light reflectance value of 25. The quote says the system takes up to 400 mm of insulation. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote StoTherm Classic S1 with 160 mm of insulation on solid masonry or concrete, with a pull-off strength below 0.08 newtons per square millimeter, bonding only, for an unevenness of 2 cm per meter. The finish is render in a shade with a light reflectance value of 12. The facade must take an impact of 60 joules. The quote says the build resists 60 joules. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote StoTherm Classic S1 with 160 mm of insulation on solid masonry or concrete, with a pull-off strength below 0.08 newtons per square millimeter, bonding and dowels, for an unevenness of 2 cm per meter. The finish is render in a shade with a light reflectance value of 12. The facade must take an impact of 60 joules with the high-impact two-layer build. The quote says the build resists 120 joules. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote StoTherm Classic S1 with 160 mm of insulation on solid masonry or concrete, with a pull-off strength below 0.08 newtons per square millimeter, bonding and dowels, for an unevenness of 2 cm per meter. The finish is render in a shade with a light reflectance value of 18. The facade must take an impact of 60 joules with the high-impact two-layer build. The quote says the build resists 120 joules. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote StoTherm Mineral with 260 mm of insulation on solid masonry or concrete, with a pull-off strength of 0.08 newtons per square millimeter or more, bonding and dowels, for an unevenness of 2 cm per meter. The finish is ceramic or natural stone cladding in a shade with a light reflectance value of 30. The quote says the system takes up to 400 mm of insulation. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote StoTherm Mineral with 200 mm of insulation on solid masonry or concrete, with a pull-off strength of 0.08 newtons per square millimeter or more, bonding and dowels, for an unevenness of 2 cm per meter. The finish is ceramic or natural stone cladding in a shade with a light reflectance value of 30. The quote says the system takes up to 300 mm of insulation. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.