Predictika · Pump orders
An AI sales agent prepares an order for light wastewater submersible pumps: the model, the site supply, the liquid, the cable and the motor figures it quotes. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published technical data and returns a verdict, every reason and the figures it computed.
This validator models orders for the ABS MF (MF 154 W to MF 804 D) and VO (VO 354 W, VO 504 W, VO 804 D) light wastewater submersible pumps, not just the scenarios shown below.
Any order for these pump models that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Sulzer publishes no price list for these pumps, so this validator produces no price build-up or line-item quote), other Sulzer pump ranges, explosion-protected versions, accessories, installation and pump curves or duty points. Total weight is computed from the data sheet unit weight; the data sheet does not define the KS version beyond its float switch and 3 m cable note, so that is all the validator uses.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Supply voltage and phase that must match the pump model | Only with care A product rule per model and supply; twelve models means twelve entries to keep in step with the data sheet. | The supply and the model are in one request and the match is checked on every call. |
| Solids passage and liquid temperature limits that depend on the model | Only with care A lookup per model compared with a value on another line, plus a temperature rule with a short-term exception; it works but needs care. | The passage is looked up from the model and compared with the liquid on every call; the short-term duty is checked with the rest. |
| Cable options that depend on both the version and the series | Only with workarounds The 3 m cable depends on the KS version and is barred on VO pumps, so it needs a cross-field rule that interacts with the others. | The cable, the version and the model are in one request, so the conflict is found whichever order the choices arrive in. |
| Stated figures that must equal the data sheet | Only with care A stated figure is a free-entry field; a rule can compare it with a looked-up value, but someone has to write and maintain that comparison for every model. | The stated figures travel with the order and are compared with the data sheet values on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order has 0 pumps; at least 1 is needed. |
| 2 | The site supply does not match the pump motor; the data sheet lists single-phase pumps for 220-240 V and three-phase pumps for 400 V. |
| 3 | The liquid carries solids up to 41 mm, but this pump passes solids up to 40 mm. |
| 4 | The liquid carries solids up to 8 mm, but this pump passes solids up to 7 mm. |
| 5 | The liquid is at 41 degrees C; the data sheet allows a maximum of 40 degrees C, or short term up to 60 degrees C for at most 5 minutes. |
| 6 | The liquid is above the 40 degrees C continuous limit; short-term duty up to 60 degrees C for at most 5 minutes is allowed by the data sheet, and a person should confirm the duty cycle. |
| 7 | The liquid is at 61 degrees C; the data sheet allows a maximum of 40 degrees C, or short term up to 60 degrees C for at most 5 minutes. |
| 8 | The pump would run 6 minutes in liquid above 40 degrees C; the data sheet allows up to 5 minutes at short-term temperatures up to 60 degrees C. |
| 9 | The 3 m cable is offered only with the KS pump (supplied with a float switch). |
| 10 | A cable length of 15 m is not offered; the data sheet lists 3, 10, 20 and 30 m. |
| 11 | A cable length of 0 m is not offered; the data sheet lists 3, 10, 20 and 30 m. |
| 12 | The 3 m cable is not available on VO pumps; for external use the data sheet requires a fixed cable of at least 10 m (VDE regulations). |
| 13 | The order states a motor output (P2) of 800 W; the data sheet gives 700 W for this model. |
| 14 | The order states a rated current of 4 A; the data sheet gives 4.8 A for this model. |
| 15 | The order states a motor output (P2) of 420 W; the data sheet gives 700 W for this model. |
| 16 | The order states a rated current of 2.8 A; the data sheet gives 4.8 A for this model. |
| 17 | The liquid carries solids up to 25 mm, but this pump passes solids up to 7 mm. |
| 18 | The liquid is at 70 degrees C; the data sheet allows a maximum of 40 degrees C, or short term up to 60 degrees C for at most 5 minutes. |
| 19 | The order states a rated current of 0.001 A; the data sheet gives 4.8 A for this model. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 12 Sulzer ABS MF 154 W submersible pumps for a three-phase 400 V supply, with a 15 m cable, pumping liquid at 25 degrees C that carries solids up to 35 mm. The order states a motor output (P2) of 420 W and a rated current of 2.8 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 Sulzer ABS MF 354 W submersible pumps for a single-phase 220-240 V supply, with a 20 m cable, pumping liquid at 25 degrees C that carries solids up to 35 mm. The order states a motor output (P2) of 700 W and a rated current of 4.8 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 6 Sulzer ABS MF 504 W submersible pumps for a single-phase 220-240 V supply, with a 20 m cable, pumping liquid at 48 degrees C that carries solids up to 30 mm. The order states a motor output (P2) of 800 W and a rated current of 9 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 6 Sulzer ABS MF 504 W submersible pumps for a single-phase 220-240 V supply, with a 20 m cable, pumping liquid at 48 degrees C that carries solids up to 30 mm. The pumps would run in that liquid for 8 minutes at a time. The order states a motor output (P2) of 1,450 W and a rated current of 9 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 6 Sulzer ABS MF 504 W submersible pumps for a single-phase 220-240 V supply, with a 20 m cable, pumping liquid at 48 degrees C that carries solids up to 30 mm. The pumps would run in that liquid for 4 minutes at a time. The order states a motor output (P2) of 1,450 W and a rated current of 9 A. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 8 Sulzer VO 804 D submersible pumps for a three-phase 400 V supply, with a 3 m cable, pumping liquid at 20 degrees C that carries solids up to 7 mm. The order states a motor output (P2) of 1,800 W and a rated current of 4.1 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 8 Sulzer VO 804 D submersible pumps for a three-phase 400 V supply, with a 10 m cable, pumping liquid at 20 degrees C that carries solids up to 7 mm. The order states a motor output (P2) of 1,800 W and a rated current of 4.1 A. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.