Predictika · Optical LAN quotes
An AI sales agent prepares a Tellabs Optical LAN quote for a hotel, hospital or campus: FlexSym OLT1 optical line terminals, FlexSym ONT202, ONT203W, ONT224 and ONT228 optical network terminals, passive splitters, uplink optics, battery backup, Panorama PON Manager licenses, installation and support. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of PON capacity, split ratio, optical loss, PoE, uplinks, battery runtime, licenses, service level, lead time and discount, and returns a verdict, every reason, a line-item quote and the figures it computed.
This validator models Tellabs Optical LAN quotes built from the FlexSym product names found in public search results, not just the scenarios shown below.
Any Tellabs Optical LAN quote that touches these products, limits and services is in scope — not only the scenarios pictured here. Not covered: GPON-only ONTs, POTS and coax interfaces, other Tellabs product lines, taxes, freight and regional rate cards. The Tellabs product names are real; the port counts, PoE budgets, loss budgets and every price on this page are typical or invented for illustration.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Split ratio, PON ports and protection together | Only with workarounds Each PON port serves a number of ONTs set by the split ratio, and protection switching uses a second port for every active one. A CPQ holds ONTs, OLTs and splitters as separate lines, so a rule has to roll up the ONT count and compare it with ports times split, with protection doubling the ports. | ONT counts, split ratio, PON ports and protection are inputs, and capacity is compared on every call. |
| Optical loss against the PON optics budget | Only with workarounds The splitter, the fiber run and the connectors add up to a loss that must stay under the budget of the optics class and PON mode. A flat quote carries none of those figures, so an engineer checks the link budget on a spreadsheet. | Split ratio, distance, connectors, PON mode and optics class are inputs; the loss and the budget are computed and compared. |
| PoE budget per ONT model | Only with care Each ONT model powers a different load, and the devices behind it vary by room type. A rule per model is possible, but it needs the draw of the devices as an input and someone to keep the limits current. | The draw per ONT model is an input and is compared with each model's budget on every call. |
| Battery runtime against the equipment load | Only with workarounds The cabinets needed depend on the watts of every ONT and OLT and on the hours the customer needs, and a hospital needs at least 8. That is arithmetic across lines that a quote does not do on its own. | Load, runtime and cabinet capacity are computed together and compared. |
| Service level against protection, power and support | Only with workarounds A Critical service level needs dual-homed OLTs, a redundant power supply and Mission Critical support. Each is a separate line, and nothing connects the promise on the first page to the lines on the third. | The promised level, the protection, the power supply and the support tier are checked against each other. |
| A stated total that has to agree with the quote | Only with workarounds Thousands of ONTs, licenses, installation and several years of support make a total that can drift from what is typed on the quote without anyone noticing. | The total is computed from the choices and compared with the total the quote states. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The quote has 5 years of support, a long price commitment, so a person should confirm. |
| 2 | The quote has 2 years of support; support is quoted for 1, 3 or 5 years. |
| 3 | The quote includes no Tellabs product or service, so there is nothing to price. |
| 4 | The quote has 410 ONTs and no FlexSym OLT1 to serve them. |
| 5 | The quote needs 28 PON ports counting protection ports, and 0 FlexSym OLT1 units provide 0. |
| 6 | The quote runs the PON feeder over multimode fiber; a passive optical LAN needs single-mode fiber between the OLT, the splitters and the ONTs. |
| 7 | The quote has a feeder run of 201 hundred meters; the PON reach is at most 20 kilometers. |
| 8 | The quote uses a split ratio of 1 to 24; passive splitters come in 1 to 8, 16, 32 and 64. |
| 9 | The quote runs the PON ports in GPON mode, and the FlexSym ONTs are 10 gigabit symmetrical XGS-PON devices. |
| 10 | The quote has 449 ONTs, and 14 PON ports at the chosen split ratio serve 448. |
| 11 | The optical path loses 2,904 hundredths of a decibel in the splitter, fiber and connectors, and the PON optics allow 2,900. |
| 12 | The powered devices behind each FlexSym ONT202 draw 31 watts; an ONT202 supplies up to 30 watts. |
| 13 | The powered devices behind each FlexSym ONT203W draw 16 watts; an ONT203W supplies up to 15 watts. |
| 14 | The powered devices behind each FlexSym ONT224 draw 61 watts; an ONT224 supplies up to 60 watts. |
| 15 | The powered devices behind each FlexSym ONT228 draw 121 watts; an ONT228 supplies up to 120 watts. |
| 16 | The quote has 2 OLTs and no uplink on them. |
| 17 | The quote has 5 uplinks on each OLT; a FlexSym OLT1 has 4 uplink ports. |
| 18 | The quote has 40 gigabit uplinks; the uplink optics are 10 or 25 gigabit. |
| 19 | The uplink optic and the uplink fiber do not match; short-reach optics need multimode fiber and long-reach optics need single-mode fiber. |
| 20 | The uplink run is 101 meters, and the chosen optic reaches 100 meters. |
| 21 | The PON ports can deliver 160,000 megabits per second downstream and the uplinks carry 60,000 megabits per second, between 2 to 1 and 4 to 1 oversubscription, so a network engineer should confirm. |
| 22 | The PON ports can deliver 160,000 megabits per second downstream, and the uplinks carry 30,000; more than 4 to 1 oversubscription is not allowed. |
| 23 | The equipment draws 10,540 watts, so 4 hours of runtime needs 42,160 watt-hours, and the battery cabinets hold 40,000. |
| 24 | The quote gives a hospital 7 hours of battery runtime; hospital deployments are quoted with at least 8 hours. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Tellabs Optical LAN for a hotel with 2,372 FlexSym ONTs: 2,000 ONT203W, 300 ONT202, 60 ONT224 and 12 ONT228. The powered devices draw 20 watts behind each ONT202, 5 watts behind each ONT203W, 75 watts behind each ONT224 and 80 watts behind each ONT228. It runs XGS-PON on 3 FlexSym OLT1 units with 38 PON ports at a split of 1 to 64, with no protection switching and Class B Plus optics. The feeder is 3,000 meters of single-mode fiber with 12 connector pairs. Each OLT has 1 uplink of 10 gigabit long-reach optics over 2,000 meters of single-mode fiber. Battery backup is 20 cabinets for 4 hours of runtime. Panorama PON Manager is licensed for 2,000 ONTs. The service level is High with Premium support for 3 years. The customer needs it in 20 weeks. The discount is $60,000. The quote states $995,014. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Tellabs Optical LAN for a hotel with 2,372 FlexSym ONTs: 2,000 ONT203W, 300 ONT202, 60 ONT224 and 12 ONT228. The powered devices draw 20 watts behind each ONT202, 5 watts behind each ONT203W, 55 watts behind each ONT224 and 80 watts behind each ONT228. It runs XGS-PON on 10 FlexSym OLT1 units with 75 PON ports at a split of 1 to 32, with Type B protection switching and Class B Plus optics. The feeder is 3,000 meters of single-mode fiber with 12 connector pairs. Each OLT has 2 uplinks of 10 gigabit long-reach optics over 2,000 meters of single-mode fiber. Battery backup is 33 cabinets for 4 hours of runtime. Panorama PON Manager is licensed for 2,372 ONTs. The service level is High with Premium support for 3 years. The customer needs it in 20 weeks. The discount is $190,000. The quote states $1,098,834. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a Tellabs Optical LAN for a hotel with 2,372 FlexSym ONTs: 2,000 ONT203W, 300 ONT202, 60 ONT224 and 12 ONT228. The powered devices draw 20 watts behind each ONT202, 5 watts behind each ONT203W, 55 watts behind each ONT224 and 80 watts behind each ONT228. It runs XGS-PON on 10 FlexSym OLT1 units with 75 PON ports at a split of 1 to 32, with Type B protection switching and Class B Plus optics. The feeder is 3,000 meters of single-mode fiber with 12 connector pairs. Each OLT has 2 uplinks of 25 gigabit long-reach optics over 2,000 meters of single-mode fiber. Battery backup is 33 cabinets for 4 hours of runtime. Panorama PON Manager is licensed for 2,372 ONTs. The service level is High with Premium support for 3 years. The customer needs it in 20 weeks. The discount is $90,000. The quote states $1,208,834. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Tellabs Optical LAN for a hospital with 1,440 FlexSym ONTs: 900 ONT203W, 400 ONT202, 120 ONT224 and 20 ONT228. The powered devices draw 20 watts behind each ONT202, 8 watts behind each ONT203W, 45 watts behind each ONT224 and 90 watts behind each ONT228. It runs XGS-PON on 6 FlexSym OLT1 units with 45 PON ports at a split of 1 to 32, with Type B protection switching and Class B Plus optics. The feeder is 2,000 meters of single-mode fiber with 8 connector pairs. Each OLT has 2 uplinks of 25 gigabit short-reach optics over 2,000 meters of single-mode fiber. Battery backup is 29 cabinets for 4 hours of runtime. Panorama PON Manager is licensed for 1,440 ONTs. The service level is Critical with Premium support for 3 years. The customer needs it in 24 weeks. The discount is $45,000. The quote states $757,870. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Tellabs Optical LAN for a hospital with 1,440 FlexSym ONTs: 900 ONT203W, 400 ONT202, 120 ONT224 and 20 ONT228. The powered devices draw 20 watts behind each ONT202, 8 watts behind each ONT203W, 45 watts behind each ONT224 and 90 watts behind each ONT228. It runs XGS-PON on 6 FlexSym OLT1 units with 45 PON ports at a split of 1 to 32, with dual-homed Type C protection switching and Class B Plus optics. The feeder is 2,000 meters of single-mode fiber with 8 connector pairs. Each OLT has 2 uplinks of 25 gigabit long-reach optics over 2,000 meters of single-mode fiber. Each OLT has a redundant power supply. Battery backup is 58 cabinets for 8 hours of runtime. Panorama PON Manager is licensed for 1,440 ONTs. The service level is Critical with Mission Critical support for 3 years. The customer needs it in 24 weeks. The discount is $45,000. The quote states $895,510. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Tellabs Optical LAN for a campus with 900 FlexSym ONTs: 650 ONT203W, 150 ONT202, 80 ONT224 and 20 ONT228. The powered devices draw 20 watts behind each ONT202, 20 watts behind each ONT203W, 40 watts behind each ONT224 and 80 watts behind each ONT228. It runs GPON on 2 FlexSym OLT1 units with 20 PON ports at a split of 1 to 32, with no protection switching and Class B Plus optics. The feeder is 4,000 meters of multimode fiber with 6 connector pairs. Each OLT has 4 uplinks of 25 gigabit long-reach optics over 3,000 meters of single-mode fiber. Battery backup is 12 cabinets for 2 hours of runtime. Panorama PON Manager is licensed for 900 ONTs. The service level is Standard with Standard support for 1 year. The customer needs it in 6 weeks. The discount is $20,000. The quote states $351,200. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Tellabs Optical LAN for a campus with 900 FlexSym ONTs: 650 ONT203W, 150 ONT202, 80 ONT224 and 20 ONT228. The powered devices draw 20 watts behind each ONT202, 12 watts behind each ONT203W, 40 watts behind each ONT224 and 80 watts behind each ONT228. It runs XGS-PON on 2 FlexSym OLT1 units with 29 PON ports at a split of 1 to 32, with no protection switching and Class B Plus optics. The feeder is 4,000 meters of single-mode fiber with 6 connector pairs. Each OLT has 4 uplinks of 25 gigabit long-reach optics over 3,000 meters of single-mode fiber. Battery backup is 12 cabinets for 2 hours of runtime. Panorama PON Manager is licensed for 900 ONTs. The service level is Standard with Standard support for 1 year. The customer needs it in 10 weeks. The discount is $20,000. The quote states $393,770. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.