Predictika · Industrial sensor quotes
An AI sales agent prepares a quote for Turck PT1000/PT2000 pressure transmitters: the pressure range, the measuring cell, the process connection, the output, the electrical connection, the supply voltage, the loop load and the load limit it says the transmitter allows. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the type key rules Turck publishes in its catalog and returns a verdict, every reason and the figures it computed.
This validator models quotes for Turck PT1000 and PT2000 pressure transmitters, based on the public Turck PT1000/PT2000 catalog (document 100030028, 2021/05), not just the scenarios shown below.
Any quote for these transmitters that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the catalog gives none, so this page shows no price build-up), the UA output, the special types, the US-market PT-13-LI3 series, temperature specifications and the differences between the PT1000 and PT2000 lines.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Which of 62 ranges fit the ceramic or the metal cell | Only with workarounds The cell depends on the range in a table of about 60 rows, and two ranges exist only in ceramic. A rules-based CPQ needs a lookup table or a rule per range, edited whenever the catalog changes. | The range is one choice, its maximum is derived and compared with the cell on every call. |
| Connections and electrical connections that limit each other (PVDF threads, H1144, ATEX) | Only with care Each restriction ties one choice to a limit on another field, so rules have to be written and kept in step for every pair. | Every pair is checked on every call, in any order the choices arrive. |
| Supply voltage and loop load that depend on the output | Only with care The allowed supply range and the maximum load both change with the output, and the load limit is a formula in the supply voltage. | The limits are derived from the output and the supply and compared with the quote on every call. |
| The load limit the quote states | Only with care The stated number comes from a formula, so a rule has to recompute it and compare. | The stated figure is a field in the request, compared with the computed one on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | Design 10 (ceramic measuring cell) covers pressure ranges up to 60 bar or 750 psi; the selected range is higher and needs design 20 (metal measuring cell). |
| 2 | The type includes 1 choice the catalog does not mark as preferred types; a person should confirm they can be supplied. |
| 3 | The 1 bar ranges with vacuum or without it (1VR and 1R) are available only with the ceramic measuring cell, design 10. |
| 4 | The PVDF male threads (47 and 48) are limited to ranges of 16 bar or less; the selected range is higher. |
| 5 | The H1,144 M12 connector is not available with a ratiometric output. |
| 6 | The ATEX 4 to 20 mA output (IX) is listed with the M12 x 1 or EN 175,301-803 design A connector versions only. |
| 7 | The type includes 2 choices the catalog does not mark as preferred types; a person should confirm they can be supplied. |
| 8 | The supply of 6 volts is outside the operating range of the selected output. |
| 9 | The supply of 35 volts is outside the operating range of the selected output. |
| 10 | The supply of 11 volts is outside the operating range of the selected output. |
| 11 | A voltage output needs a load above 10,000 ohms; the quote has 5,000 ohms. |
| 12 | The loop load of 850 ohms is not below the limit of 850 ohms for this supply voltage. |
| 13 | The quote states a loop load limit of 1,000 ohms; the catalog formula gives 850 ohms for this supply voltage. |
| 14 | The quote has 0 transmitters; it needs at least 1. |
| 15 | The type includes 4 choices the catalog does not mark as preferred types; a person should confirm they can be supplied. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote forty Turck pressure transmitters, range 400 bar, design 10 (ceramic measuring cell), PVDF male thread 47, 4 to 20 mA output (I2), with the H1143 connector. The supply is 24 volts and the loop load is 250 ohms. The quote states that the transmitter allows a loop load of up to 850 ohms. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote forty Turck pressure transmitters, range 400 bar, design 20 (metal measuring cell), process connection 03, 4 to 20 mA output (I2), with the H1143 connector. The supply is 24 volts and the loop load is 250 ohms. The quote states that the transmitter allows a loop load of up to 850 ohms. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote sixty Turck pressure transmitters, range 10 bar, design 10 (ceramic measuring cell), process connection 03, ratiometric output (U6), with the H1144 M12 connector. The supply is 24 volts and the loop load is 20,000 ohms. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote sixty Turck pressure transmitters, range 10 bar, design 10 (ceramic measuring cell), process connection 03, voltage output (U1), with the H1144 M12 connector. The supply is 24 volts and the loop load is 20,000 ohms. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote twenty-five Turck pressure transmitters, range 250 bar, design 20 (metal measuring cell), process connection 03, ATEX 4 to 20 mA output (IX), with electrical connection CM20. The supply is 24 volts and the loop load is 750 ohms. The quote states that the transmitter allows a loop load of up to 850 ohms. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote twenty-five Turck pressure transmitters, range 250 bar, design 20 (metal measuring cell), process connection 03, ATEX 4 to 20 mA output (IX), with the DA91 DIN design A connector. The supply is 24 volts and the loop load is 650 ohms. The quote states that the transmitter allows a loop load of up to 700 ohms. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote twenty-five Turck pressure transmitters, range 250 bar, design 20 (metal measuring cell), process connection 03, 4 to 20 mA output (I2), with the H1143 connector. The supply is 24 volts and the loop load is 650 ohms. The quote states that the transmitter allows a loop load of up to 850 ohms. It is ready to send.
Verdict: Allowed.