Predictika · Thermostat and sensor orders
An AI sales agent prepares an order for UEI and Ecolink climate-control products: which thermostat, the HVAC system and its stages, the power supply and wiring, TIDE Bridges and peripherals, the control platform, Z-Wave and Zigbee sensors, and the unit count it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of what the public UEI and Ecolink sheets say and returns a verdict, every reason and the figures it computed.
This validator models orders for the thermostats named here based on the public UEI product sheets and the Ecolink Home Automation catalog, not just the scenarios shown below.
Any order for these products that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (UEI does not publish prices, so this page shows no price build-up), other UEI remotes, thermostats and sensors, Ecolink security-panel products, and anything the sheets do not state.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Limits that depend on the system type | Only with care Stage limits differ for heat pumps and standard systems and apply only to some thermostats, so each needs a rule that reads both the thermostat and the system type. | The thermostat, system type and stages are one request and are checked together. |
| Wiring conditions | Only with workarounds A required common wire depends on the supply chosen, and the jumper rule on the transformer setup, so each is a conditional rule written per thermostat. | Supply, wiring and transformer setup are checked against the thermostat on every call. |
| A stated total that must equal a sum | Only with care The unit count the order states must be compared with a sum over thermostats, bridges and sensors that rules must maintain. | The stated total is a field in the request and is compared with the computed sum. |
| Platforms that are not on a product list | Only with workarounds Each product has its own list of compatible panels and hubs; anything off the list must be routed to a person rather than rejected. | Lists are checked per product and unlisted platforms are routed for approval. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | UEI lists multi-zone control for up to 8 Comfort Line thermostats; the order has 9 TIDE thermostats. |
| 2 | The sheet says multi-zone control supports up to 8 Comfort Line thermostats and TIDE Bridges; the order has 8 TIDE thermostats and 1 TIDE Bridges, so a person should confirm how the limit counts bridges. |
| 3 | The TBZ500 and TW780 support up to 2 stages of heating on this system type; the order asks for 3. |
| 4 | The TBZ500 and TW780 support up to 3 stages of heating on this system type; the order asks for 4. |
| 5 | The TBZ500 and TW780 support up to 2 stages of cooling; the order asks for 3. |
| 6 | The TBZ500 sheet lists four AA batteries or hardwired 24 VAC; this supply is not listed, so a person should confirm it. |
| 7 | The TW780 needs wired 24 VAC power; the order specifies another supply. |
| 8 | 24 VAC operation of the TBZ500 and TW780 needs both the R wire and the common (C) wire from the HVAC system; the order has no C wire. |
| 9 | With separate heating and cooling transformers the factory-installed RC/RH jumper of the TBZ500 must be removed; the order leaves it in place. |
| 10 | The TW780 datasheet lists the HVAC modes Off, Heat and Cool; automatic changeover is not among them. |
| 11 | The TBZ500 and TW780 sheets list standard gas/electric and heat pump systems; this HVAC system type is not listed, so a person should confirm it. |
| 12 | The TBH300 is listed for conventional HVAC systems; this HVAC system type is not listed, so a person should confirm it. |
| 13 | The TBH300 is listed with 24 VAC power wiring; this supply is not listed, so a person should confirm it. |
| 14 | Battery supply is not among the supply options listed for the TIDE Dial and TIDE Touch; a person should confirm it. |
| 15 | The TIDE Dial and TIDE Touch sheets list 230 VAC and 277 VAC as works with TIDE Bridge; the order has no TIDE Bridge, so a person should confirm it. |
| 16 | UEI describes the TIDE Bridge as an accessory for the Comfort thermostat line (TIDE Dial and TIDE Touch); it is not listed for this thermostat, so a person should confirm it. |
| 17 | A TIDE Bridge supports up to 10 peripheral devices; 1 bridges give room for 10 and the order pairs 11. |
| 18 | The order pairs 3 Zigbee peripheral devices to a TIDE Bridge but includes no TIDE Bridge. |
| 19 | This control platform is not on the TBZ500 list of compatible panels and Z-Wave hubs; a person should confirm it. |
| 20 | The Ecolink catalog lists the TBH300 with Zigbee products compatible with Samsung SmartThings and Alexa Echo Hub; this control platform is not listed for the thermostat, so a person should confirm it. |
| 21 | The TIDE sheets list Amazon Alexa, Apple HomeKit and the Google Assistant; this control platform is not listed, so a person should confirm it. |
| 22 | The Ecolink catalog lists Z-Wave Plus products as compatible with Samsung SmartThings, Vera and HomeSeer; this control platform is not listed, so a person should confirm it. |
| 23 | The Ecolink catalog lists Zigbee sensors as compatible with Samsung SmartThings and Alexa Echo Hub; this control platform is not listed for the sensors, so a person should confirm it. |
| 24 | The order states 7 units in total; the items ordered add up to 5. |
| 25 | The order states 44 units in total; the items ordered add up to 40. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please prepare an order for 96 x UEI TW780. The HVAC system type is heat pump, with 2 stages of heating and 2 of cooling, powered from 24 VAC, without a common (C) wire; heating and cooling use a single transformer. Mode: automatic changeover. Control platform: none. The order states 96 units in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for 96 x UEI TW780. The HVAC system type is heat pump, with 2 stages of heating and 2 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use a single transformer. Mode: standard. Control platform: none. The order states 96 units in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare an order for 24 x Ecolink TBZ500, 30 Ecolink Z-Wave Plus sensors. The HVAC system type is conventional (standard gas/electric), with 3 stages of heating and 2 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use separate transformers, RC/RH jumper in place. Mode: standard. Control platform: Alexa Echo Hub. The order states 54 units in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for 24 x Ecolink TBZ500, 30 Ecolink Z-Wave Plus sensors. The HVAC system type is conventional (standard gas/electric), with 2 stages of heating and 2 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use separate transformers, RC/RH jumper removed. Mode: standard. Control platform: Alexa Echo Hub. The order states 54 units in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please prepare an order for 24 x Ecolink TBZ500, 30 Ecolink Z-Wave Plus sensors. The HVAC system type is conventional (standard gas/electric), with 2 stages of heating and 2 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use separate transformers, RC/RH jumper removed. Mode: standard. Control platform: Samsung SmartThings. The order states 54 units in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare an order for 10 x UEI TIDE Touch, 2 x UEI TIDE Bridge. The HVAC system type is conventional (standard gas/electric), with 1 stage of heating and 1 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use a single transformer. Mode: standard. Control platform: Apple HomeKit. 24 Zigbee peripheral devices are paired to the bridges. The order states 12 units in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for 6 x UEI TIDE Touch, 2 x UEI TIDE Bridge. The HVAC system type is conventional (standard gas/electric), with 1 stage of heating and 1 of cooling, powered from 24 VAC, with a common (C) wire; heating and cooling use a single transformer. Mode: standard. Control platform: Apple HomeKit. 20 Zigbee peripheral devices are paired to the bridges. The order states 8 units in total. It is ready to send.
Verdict: Allowed.