An AI sales agent prepares an order for a weighing system built on Model 65023 shear beam load cells: the rated capacity and unit, the number of cells, the peak and side loads, the excitation voltage, the temperatures, the trade approval, the material and profile options, and the combined capacity it states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the public Model 65023 datasheet and returns a verdict, every reason and the figures it computed.
This validator models an order for one capacity of the Model 65023 load cell at a time, based on the public Model 65023 datasheet, not just the scenarios shown below.
Any Model 65023 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the datasheet has none, so this page shows no price build-up), other load cell models, hazardous-area and Factory Mutual options, NTEP Class III intervals (the datasheet figures conflict), mounting hardware and weigh modules, and system accuracy, which depends on installation.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Capacity lists that differ by unit (10 pound and 8 kilogram capacities) | Only with workarounds Valid capacities depend on the unit, and options such as stainless steel depend on the unit as well. A rules-based CPQ needs two lists and a cross-rule, and a datasheet change means editing them. | Unit and capacity arrive in one request and are matched against the published lists on every call. |
| Trade approvals that depend on capacity and intervals | Only with care OIML is listed only for some capacities and some units, and each approval has its own interval limit, so two lookups have to agree. | Approval, capacity, unit and intervals are compared together, in any order. |
| Peak load against the combined capacity of several cells | Only with care The check multiplies cells by capacity and compares at two thresholds, one routed to a person and one blocked. | The combined capacity is computed on every call and both thresholds are applied. |
| Stated combined capacity | Only with care The stated figure is derived from the cells and capacity, so a rule has to recompute it and compare. | The stated capacity is a field in the request, compared with the computed one on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a person often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | A rated capacity of 3000 is not one of the Model 65,023 capacities for the selected unit (250 to 20,000 lbs, or 125 to 10,000 kg). |
| 2 | A rated capacity of 750 is not one of the Model 65,023 capacities for the selected unit (250 to 20,000 lbs, or 125 to 10,000 kg). |
| 3 | A rated capacity of 15,000 is not one of the Model 65,023 capacities for the selected unit (250 to 20,000 lbs, or 125 to 10,000 kg). |
| 4 | The order has 0 load cells; at least 1 is needed. |
| 5 | The datasheet lists the stainless steel option for the pound versions only. |
| 6 | The ultra low profile is listed for the 1000 to 2500 pound ranges only (1000, 1500 and 2000 lbs in the capacity list); the selected capacity is not one of them. |
| 7 | OIML approval is listed only for 1K to 10K lbs and 500 to 5000 kg capacities; 15,000 is outside that. |
| 8 | OIML approval is listed only for 1K to 10K lbs and 500 to 5000 kg capacities; 500 is outside that. |
| 9 | OIML approval is listed only for 1K to 10K lbs and 500 to 5000 kg capacities; 250 is outside that. |
| 10 | The OIML R-60 approval is for up to 3000 intervals; the order needs 3001. |
| 11 | NTEP Class IIIL is listed for up to 10,000 intervals; the order needs 10001. |
| 12 | The peak load of 20,001 is above the combined rated capacity of 20,000; it is within the 150 percent safe overload, so a person should confirm. |
| 13 | The peak load of 30,000 is above the combined rated capacity of 20,000; it is within the 150 percent safe overload, so a person should confirm. |
| 14 | The peak load of 30,001 is above 150 percent, the maximum safe central overload, of the combined rated capacity of 20,000 (4 load cells). |
| 15 | A side load of 5001 on a cell is above the safe side load, 100 percent of the rated capacity of 5000. |
| 16 | An excitation of 12 volts is above the recommended 10 volts, within the 15 volt maximum; a person should confirm. |
| 17 | An excitation of 15 volts is above the recommended 10 volts, within the 15 volt maximum; a person should confirm. |
| 18 | An excitation of 16 volts is above the 15 volt maximum. |
| 19 | The operating temperatures of 40 to 120 degrees Fahrenheit are inside the operating range but outside the compensated range of 14 to 104 degrees; a person should confirm. |
| 20 | The operating temperatures of 5 to 100 degrees Fahrenheit are inside the operating range but outside the compensated range of 14 to 104 degrees; a person should confirm. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 4 Model 65023 load cells rated 2,000 lbs each for a weighing system with a peak load of 14,000 lbs and a side load of 300 lbs on a cell, powered at 10 volts and working between 40 and 100 degrees Fahrenheit, with no trade approval. The order states a combined capacity of 8,000 lbs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 4 Model 65023 load cells rated 5,000 lbs each for a weighing system with a peak load of 14,000 lbs and a side load of 300 lbs on a cell, powered at 10 volts and working between 40 and 100 degrees Fahrenheit, with no trade approval. The order states a combined capacity of 20,000 lbs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 4 Model 65023 load cells rated 15,000 lbs each for a weighing system with a peak load of 30,000 lbs and a side load of 500 lbs on a cell, powered at 10 volts and working between 40 and 100 degrees Fahrenheit, with OIML R-60 approval for 2,000 intervals. The order states a combined capacity of 60,000 lbs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 4 Model 65023 load cells rated 10,000 lbs each for a weighing system with a peak load of 30,000 lbs and a side load of 500 lbs on a cell, powered at 10 volts and working between 40 and 100 degrees Fahrenheit, with OIML R-60 approval for 2,000 intervals. The order states a combined capacity of 40,000 lbs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 4 Model 65023 load cells rated 5,000 lbs each with the ultra low profile for a weighing system with a peak load of 12,000 lbs and a side load of 500 lbs on a cell, powered at 12 volts and working between 40 and 100 degrees Fahrenheit, with no trade approval. The order states a combined capacity of 20,000 lbs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 4 Model 65023 load cells rated 5,000 lbs each for a weighing system with a peak load of 12,000 lbs and a side load of 500 lbs on a cell, powered at 12 volts and working between 40 and 100 degrees Fahrenheit, with no trade approval. The order states a combined capacity of 20,000 lbs. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 4 Model 65023 load cells rated 5,000 lbs each for a weighing system with a peak load of 12,000 lbs and a side load of 500 lbs on a cell, powered at 10 volts and working between 40 and 100 degrees Fahrenheit, with no trade approval. The order states a combined capacity of 20,000 lbs. It is ready to send.
Verdict: Allowed.