Predictika · Fieldbus I/O node orders
An AI sales agent prepares an order for a WAGO I/O System 750 node (a controller, I/O modules and an end module) and states the internal current the modules draw. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published data-sheet figures and returns a verdict, every reason and the figures it computed.
This validator models node orders for the WAGO I/O System 750 using figures from WAGO's public data sheets, not just the scenarios shown below.
Any node order built from these parts is in scope — not only the scenarios pictured here. Not covered: prices (none were used, so this validator produces no price build-up or line-item quote), other controllers and couplers, other I/O modules, bus extension beyond 64 modules, the field-side (24 V) supply and power jumper contact limits, process image size, and WAGO products outside the 750 series.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Modules that together draw more 5 V current than the controller supplies | Only with workarounds The current each module type draws has to be summed across the whole node and compared with a budget, which takes calculated fields and a rule per controller rather than a simple compatibility table. | Each module count is in the request; the total current is computed and compared with the available current on every call. |
| More than 64 modules on one node | Only with care The limit counts modules of every type, including supply modules, so it needs a running total that is kept in step with the parts list. | The total is computed from all module counts and compared with the limit on every call. |
| A stated total current that disagrees with the data sheets | Only with workarounds The figure the agent states is free text or a separate field, so it takes an extra rule that compares it with the computed value. | The stated current is part of the request and is compared on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The node has no end module 750-600; the end module is snapped onto the node after the last I/O module and completes the internal data circuit. |
| 2 | The node has 65 I/O modules; the controller data sheet lists 64 I/O modules per node (up to 250 only with bus extension, which is not modeled). |
| 3 | The I/O modules need 1717 mA of internal 5 V current but the node supplies 1700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 4 | The I/O modules need 1755 mA of internal 5 V current but the node supplies 1700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 5 | The node includes 750-613 system power supply modules; the data used here does not give their own consumption or their position along the node, so a person should confirm the placement. |
| 6 | The I/O modules need 3770 mA of internal 5 V current but the node supplies 3700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 7 | The order states an internal current consumption of 500 mA; the data sheets add up to 431 mA. |
| 8 | The I/O modules need 2140 mA of internal 5 V current but the node supplies 1700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 9 | The I/O modules need 1950 mA of internal 5 V current but the node supplies 1700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 10 | The node has 80 I/O modules; the controller data sheet lists 64 I/O modules per node (up to 250 only with bus extension, which is not modeled). |
| 11 | The I/O modules need 2560 mA of internal 5 V current but the node supplies 1700 mA; an additional system power supply module 750-613 (2000 mA) is needed. |
| 12 | The order states an internal current consumption of 0 mA; the data sheets add up to 431 mA. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 24 x 750-430 digital input modules, 16 x 750-530 digital output modules, 20 x 750-455 analog input modules and 6 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 2498 mA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 24 x 750-430 digital input modules, 16 x 750-530 digital output modules, 10 x 750-455 analog input modules and 2 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 1588 mA. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 8 x 750-430 digital input modules, 8 x 750-530 digital output modules, 27 x 750-455 analog input modules and 0 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 2091 mA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 8 x 750-430 digital input modules, 8 x 750-530 digital output modules, 27 x 750-455 analog input modules and 0 x 750-550 analog output modules, with 1 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 2091 mA. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 8 x 750-430 digital input modules, 8 x 750-530 digital output modules, 20 x 750-455 analog input modules and 0 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 1636 mA. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 8 x 750-430 digital input modules, 4 x 750-530 digital output modules, 2 x 750-455 analog input modules and 1 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 0 end module(s) 750-600. The order states a total internal current consumption of 400 mA. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a WAGO I/O System 750 node on a 750-880 controller with 8 x 750-430 digital input modules, 4 x 750-530 digital output modules, 2 x 750-455 analog input modules and 1 x 750-550 analog output modules, with 0 system power supply module(s) 750-613 and 1 end module(s) 750-600. The order states a total internal current consumption of 431 mA. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.