Predictika · Three-phase motor orders
An AI sales agent prepares a quote for a W22 IE3 three-phase motor: rated output, number of poles, frame size, full-load current, and the ambient temperature and altitude of the site. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published catalog tables and returns a verdict, every reason and the figures it computed.
This validator models the W22 IE3 Premium Efficiency line in the 50 Hz, 400 V catalog tables, not just the scenarios shown below.
Any quote for these motors that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the catalog has no price list, so this validator produces no price build-up or line-item quote), the IE1, IE2 and IE4 lines, 60 Hz and other voltages, variable-speed drive operation, options and accessories, and the ratings of optional frames, which are flagged for a person to confirm.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A rated output and pole count the catalog does not list | Only with care Every listed rating must be a product choice; anything off the list is only caught if someone keeps the product rules in step with the catalog. | The listed ratings are part of the model; an unlisted output and pole count is blocked on every call. |
| Frame size and full-load current that do not match the catalog rating | Only with workarounds Roughly 155 ratings each carry a frame size and a current. A lookup table plus validation rules can compare them, but someone has to build and maintain all of it. | Frame size and current travel with the quote and are compared with the catalog row on every call. |
| A load that exceeds the derated output at the site's ambient temperature and altitude | Only with workarounds The correction factor depends on two inputs at once, 135 table points. It takes a two-way lookup table and custom calculation rules. | The correction table is part of the model; the planned load is compared with the derated output on every call. |
| An optional frame that needs approval rather than a block | Only with care Three outcomes (standard, optional, not listed) per rating means separate rules and an approval step for each case. | Standard, optional and unlisted frames are told apart on every call, and optional frames go to a person. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | No W22 IE3 motor with this rated output and number of poles is listed in the 50 Hz, 400 V catalog table. |
| 2 | The quote lists frame size 250S/M, which the catalog shows only as an optional frame for this output and number of poles; a person must confirm the optional-frame data. |
| 3 | The quote lists frame size 63, which is neither the standard frame nor a listed optional frame for this output and number of poles. |
| 4 | The quote states a full-load current of 130 A at 400 V, but the catalog lists 134 A for this motor. |
| 5 | The planned load is 80,000 W, but at this ambient temperature and altitude the catalog allows at most 75,000 W from this motor. |
| 6 | The planned load is 71,251 W, but at this ambient temperature and altitude the catalog allows at most 71,250 W from this motor. |
| 7 | The planned load is 62,300 W, but at this ambient temperature and altitude the catalog allows at most 62,250 W from this motor. |
| 8 | The ambient temperature and altitude on the quote are not a point in the catalog derating table (ambient 10 to 80 C in 5 C steps, altitude 1,000 to 5,000 m in 500 m steps; up to 1,000 m counts as 1,000 m). |
| 9 | The quote states a full-load current of 700 A at 400 V, but the catalog lists 762 A for this motor. |
| 10 | The planned load is 380,000 W, but at this ambient temperature and altitude the catalog allows at most 300,000 W from this motor. |
| 11 | The quote lists frame size 355M/L, which the catalog shows only as an optional frame for this output and number of poles; a person must confirm the optional-frame data. |
| 12 | The quote lists frame size 355M/L, which is neither the standard frame nor a listed optional frame for this output and number of poles. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote one WEG W22 IE3 motor: 132 kW, 4 poles, frame size 280S/M, 50 Hz, 400 V. The quote states a full-load current of 220 A and a planned load of 132 kW, for a site at 45 C and 1,000 m altitude. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one WEG W22 IE3 motor: 132 kW, 4 poles, frame size 315S/M, 50 Hz, 400 V. The quote states a full-load current of 231 A and a planned load of 125 kW, for a site at 45 C and 1,000 m altitude. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one WEG W22 IE3 motor: 200 kW, 6 poles, frame size 355M/L, 50 Hz, 400 V. The quote states a full-load current of 376 A and a planned load of 200 kW, for a site at 50 C and 2,500 m altitude. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one WEG W22 IE3 motor: 250 kW, 6 poles, frame size 355M/L, 50 Hz, 400 V. The quote states a full-load current of 476 A and a planned load of 200 kW, for a site at 50 C and 2,500 m altitude. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote one WEG W22 IE3 motor: 80 kW, 4 poles, frame size 280S/M, 50 Hz, 400 V. The quote states a full-load current of 134 A and a planned load of 78 kW, for a site at 40 C and 1,000 m altitude. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote one WEG W22 IE3 motor: 75 kW, 4 poles, frame size 250S/M, 50 Hz, 400 V. The quote states a full-load current of 134 A and a planned load of 75 kW, for a site at 40 C and 1,000 m altitude. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote one WEG W22 IE3 motor: 75 kW, 4 poles, frame size 280S/M, 50 Hz, 400 V. The quote states a full-load current of 134 A and a planned load of 75 kW, for a site at 40 C and 1,000 m altitude. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.