Predictika · Pressure transmitter orders

An AI sales agent's pressure transmitter order, checked before it goes out

An AI sales agent prepares an order for a WIKA model A-10 pressure transmitter: measuring range, output signal and supply, process and electrical connection, temperature range and approvals. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the combination limits in the public A-10 data sheet and returns a verdict, every reason and the figures it computed.

Scope: WIKA A-10 pressure transmitter orders: measuring range, output signal and supply voltage, non-linearity, process and electrical connection, temperature range, approvals, overpressure and loop load. See everything this validator covers

This validator models orders for the A-10 transmitter built from the public data sheet limits below, not just the scenarios shown.

  • Measuring range — gauge ranges from 50 mbar to 1,000 bar and absolute ranges from 100 mbar to 25 bar; the overpressure limit follows the data sheet bands (for example 2 times the range from 1.6 bar up to 600 bar) and the peak operating pressure is compared with it.
  • Output and supply — 4 to 20 mA, 0 to 10 V, 0 to 5 V, 1 to 5 V, 0.5 to 4.5 V and ratiometric outputs, each with its supply voltage range (standard up to 30 V DC or the 8 to 35 V option); the maximum load of the current output is (supply voltage minus 8 V) divided by 0.02 A.
  • Accuracy options — the improved 0.25 % non-linearity is not available at ranges of 0.1 bar or less, with the 0 to 5 V output or with the 8 to 35 V supply; the 0 to 5 V output is not offered at 0.1 bar or less.
  • Connections — G 1/8 B and 1/8 NPT are limited to 400 bar, the flange connection to 100 bar, and the SAE connection to -20 degrees C and above; the angular DIN connectors are IP65 while the M12 connector and cable outlet are IP67.
  • Temperature and approvals — the -40 to +100 degrees C range needs the 4 to 20 mA output and a housed site protected from condensation, and is not combined with the DNV or cULus approvals; the 8 to 35 V supply is limited to 80 degrees C.

Any A-10 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none were used, so this validator produces no price build-up or line-item quote), other WIKA models, the full list of standard ranges and units, seal materials, pressure port and T-restrictor options, the overpressure of ranges above 600 bar, and limits where the two data-sheet copies read differed (for example UL and DNV range limits). Supply voltages are entered in whole volts.

The AI sales agentBuilds the transmitter order from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

8 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
A pressure range that decides which connections, options and outputs are allowedOnly with care
The 0.1 bar, 100 bar, 400 bar and 600 bar boundaries each need their own rule, and each is easy to miss when a range is picked from a list.
The range is one number in the request and every boundary is checked on every call.
An output signal whose supply voltage range depends on the output and the supply optionOnly with care
The allowed voltages belong to the output and supply choices, so a lookup table and a separate validation rule are needed.
The output, supply option and voltage are compared together on every call.
A maximum load that follows from the supply voltage, and an overpressure limit that follows from the rangeOnly with workarounds
These are formulas rather than choices, so they need calculated fields and a rule that compares them with what the agent stated.
Both figures are computed from the order and compared with the agent's stated figures.
A temperature range that restricts the output, the site and the approvalsOnly with workarounds
One option constrains several others, so each pairing needs a rule and the set grows with every option.
The temperature range is checked against output, site, supply and approvals in one pass.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1A measuring range of 0 to 49 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar).
2A measuring range of 0 to 1,000,001 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar).
3A measuring range of 0 to 25,001 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar).
4The improved 0.25 % non-linearity is not available for ranges of 0.1 bar or less, with a 0 to 5 V output, or with the 8 to 35 V supply option.
5The 0 to 5 V output is not available for measuring ranges of 0.1 bar or less.
6A supply of 7 V DC is outside the 8 to 30 V DC that this output signal and supply option allow.
7The loop load of 0 ohm is above the maximum load of -50 ohm at this supply voltage.
8A supply of 31 V DC is outside the 8 to 30 V DC that this output signal and supply option allow.
9A supply of 36 V DC is outside the 8 to 35 V DC that this output signal and supply option allow.
10A supply of 13 V DC is outside the 14 to 30 V DC that this output signal and supply option allow.
11A supply of 24 V DC is outside the 5 V DC that this output signal and supply option allow.
12The 8 to 35 V supply option is only possible for medium temperatures up to 80 degrees C, and an extended temperature range is ordered.
13The -40 to +100 degrees C range is offered with the 4 to 20 mA current output only.
14The -40 to +100 degrees C range is only possible when the installation site is housed and protected from condensation.
15This process connection (G 1/8 B or 1/8 NPT) is limited to measuring ranges of 400 bar; the range is 401,000 mbar.
16The G 1/4 female connection with flange is limited to measuring ranges of 100 bar; the range is 101,000 mbar.
17The SAE J514 connection is limited to medium temperatures of -20 degrees C and above, and an extended low-temperature range is ordered.
18The angular DIN connectors are IP65; the order requires IP67.
19Reverse-polarity protection is not available with the ratiometric output.
20The DNV and cULus approvals are not available with the -40 to +100 degrees C medium temperature range.
21The loop load of 801 ohm is above the maximum load of 800 ohm at this supply voltage.
22The peak operating pressure of 20,001 mbar is above the overpressure limit of 20,000 mbar for this range.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. A cold-site order: A cold-site order with a voltage output, no condensation protection and a DNV approval

The agent's request. Please quote 20 WIKA A-10 pressure transmitters with a gauge range of 0 to 16 bar, a 1 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of -40 to +100 degrees C, with the standard 0.5 % non-linearity, with the DNV approval, a peak operating pressure of 20 bar. The quote states an overpressure limit of 32 bar. It is ready to send.

Verdict: Blocked.

  • -40 degrees C needs a 4 to 20 mA output. The -40 to +100 degrees C range is offered with the 4 to 20 mA current output only.
  • -40 degrees C needs a protected site. The -40 to +100 degrees C range is only possible when the installation site is housed and protected from condensation.
  • Approval not available at -40 degrees C. The DNV and cULus approvals are not available with the -40 to +100 degrees C medium temperature range.

2. A cold-site order: The agent resubmits after fixing the errors

The agent's request. Please quote 20 WIKA A-10 pressure transmitters with a gauge range of 0 to 16 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of -40 to +100 degrees C on a housed site protected from condensation, with the standard 0.5 % non-linearity, a peak operating pressure of 20 bar and a loop load of 600 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 32 bar. It is ready to send.

Verdict: Allowed.

  • Order summary. 20 A-10 transmitters, range 0 to 16,000 mbar; overpressure limit 32,000 mbar (0 means not modeled above 600 bar); supply 8 to 30 V DC allowed; maximum loop load 800 ohm (4 to 20 mA only).

3. A 600 bar line: A 600 bar range on a G 1/8 B connection

The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/8 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm. It is ready to send.

Verdict: Blocked.

  • Connection limited to 400 bar. This process connection (G 1/8 B or 1/8 NPT) is limited to measuring ranges of 400 bar; the range is 600,000 mbar.

4. A 600 bar line: The agent resubmits after fixing the errors

The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 female with flange process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 1,200 bar. It is ready to send.

Verdict: Blocked.

  • Flange connection limited to 100 bar. The G 1/4 female connection with flange is limited to measuring ranges of 100 bar; the range is 600,000 mbar.

5. A 600 bar line: The agent resubmits after fixing the errors

The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 1,200 bar. It is ready to send.

Verdict: Allowed.

  • Order summary. 40 A-10 transmitters, range 0 to 600,000 mbar; overpressure limit 1,200,000 mbar (0 means not modeled above 600 bar); supply 8 to 30 V DC allowed; maximum loop load 800 ohm (4 to 20 mA only).

6. A washdown order: A washdown order with IP67 on a DIN connector and 0.25 % non-linearity on the 8 to 35 V supply

The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 4 to 20 mA output powered at 31 V DC (the 8 to 35 V DC option), a G 1/4 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the improved 0.25 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar and a loop load of 900 ohm. The quote states a maximum load of 1,150 ohm and an overpressure limit of 8 bar. It is ready to send.

Verdict: Blocked.

  • 0.25 % non-linearity not available. The improved 0.25 % non-linearity is not available for ranges of 0.1 bar or less, with a 0 to 5 V output, or with the 8 to 35 V supply option.
  • IP67 not met by the DIN connector. The angular DIN connectors are IP65; the order requires IP67.

7. A washdown order: The agent resubmits after fixing the errors

The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 0 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of 0 to 80 degrees C, with the improved 0.25 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar. The quote states an overpressure limit of 8 bar. It is ready to send.

Verdict: Blocked.

  • 0.25 % non-linearity not available. The improved 0.25 % non-linearity is not available for ranges of 0.1 bar or less, with a 0 to 5 V output, or with the 8 to 35 V supply option.

8. A washdown order: The agent resubmits after fixing the errors

The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 0 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar. The quote states an overpressure limit of 8 bar. It is ready to send.

Verdict: Allowed.

  • Order summary. 12 A-10 transmitters, range 0 to 4,000 mbar; overpressure limit 8,000 mbar (0 means not modeled above 600 bar); supply 8 to 30 V DC allowed; maximum loop load 0 ohm (4 to 20 mA only).

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares an order for a WIKA model A-10 pressure transmitter: measuring range, output signal and supply, process and electrical connection, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the combination limits in the public A-10 data sheet and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote 20 WIKA A-10 pressure transmitters with a gauge range of 0 to 16 bar, a 1 to 5 V output powered at 24 V DC. The quote states an overpressure limit of 32 bar. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with three findings, all in one answer. The -40 to +100 degrees C range is offered with the 4 to 20 mA current output only. The -40 to +100 degrees C range is only possible when the installation site is housed and protected from condensation. The DNV and cULus approvals are not available with the -40 to +100 degrees C medium temperature range.
  6. The validator returned three blocking findings in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for a temperature range that restricts the output, the site and the approvals, a rules-based CPQ can do this only with workarounds.
  8. Now the agent resubmits.
  9. The corrected request. It changes the output signal to 4 to 20 mA, the site protected from condensation to yes and the DNV approval to no. It sets the loop load to 600 ohm and the stated maximum load as to 800 ohm.
  10. It calls the validator again.
  11. This time the validator clears it.
  12. All three earlier findings are cleared, and the validator's figure matches the quote.