Predictika · Pressure transmitter orders
An AI sales agent prepares an order for a WIKA model A-10 pressure transmitter: measuring range, output signal and supply, process and electrical connection, temperature range and approvals. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the combination limits in the public A-10 data sheet and returns a verdict, every reason and the figures it computed.
This validator models orders for the A-10 transmitter built from the public data sheet limits below, not just the scenarios shown.
Any A-10 order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none were used, so this validator produces no price build-up or line-item quote), other WIKA models, the full list of standard ranges and units, seal materials, pressure port and T-restrictor options, the overpressure of ranges above 600 bar, and limits where the two data-sheet copies read differed (for example UL and DNV range limits). Supply voltages are entered in whole volts.
8 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| A pressure range that decides which connections, options and outputs are allowed | Only with care The 0.1 bar, 100 bar, 400 bar and 600 bar boundaries each need their own rule, and each is easy to miss when a range is picked from a list. | The range is one number in the request and every boundary is checked on every call. |
| An output signal whose supply voltage range depends on the output and the supply option | Only with care The allowed voltages belong to the output and supply choices, so a lookup table and a separate validation rule are needed. | The output, supply option and voltage are compared together on every call. |
| A maximum load that follows from the supply voltage, and an overpressure limit that follows from the range | Only with workarounds These are formulas rather than choices, so they need calculated fields and a rule that compares them with what the agent stated. | Both figures are computed from the order and compared with the agent's stated figures. |
| A temperature range that restricts the output, the site and the approvals | Only with workarounds One option constrains several others, so each pairing needs a rule and the set grows with every option. | The temperature range is checked against output, site, supply and approvals in one pass. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | A measuring range of 0 to 49 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar). |
| 2 | A measuring range of 0 to 1,000,001 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar). |
| 3 | A measuring range of 0 to 25,001 mbar is outside the range the data sheet lists for this pressure type (gauge 50 mbar to 1,000 bar; absolute 100 mbar to 25 bar). |
| 4 | The improved 0.25 % non-linearity is not available for ranges of 0.1 bar or less, with a 0 to 5 V output, or with the 8 to 35 V supply option. |
| 5 | The 0 to 5 V output is not available for measuring ranges of 0.1 bar or less. |
| 6 | A supply of 7 V DC is outside the 8 to 30 V DC that this output signal and supply option allow. |
| 7 | The loop load of 0 ohm is above the maximum load of -50 ohm at this supply voltage. |
| 8 | A supply of 31 V DC is outside the 8 to 30 V DC that this output signal and supply option allow. |
| 9 | A supply of 36 V DC is outside the 8 to 35 V DC that this output signal and supply option allow. |
| 10 | A supply of 13 V DC is outside the 14 to 30 V DC that this output signal and supply option allow. |
| 11 | A supply of 24 V DC is outside the 5 V DC that this output signal and supply option allow. |
| 12 | The 8 to 35 V supply option is only possible for medium temperatures up to 80 degrees C, and an extended temperature range is ordered. |
| 13 | The -40 to +100 degrees C range is offered with the 4 to 20 mA current output only. |
| 14 | The -40 to +100 degrees C range is only possible when the installation site is housed and protected from condensation. |
| 15 | This process connection (G 1/8 B or 1/8 NPT) is limited to measuring ranges of 400 bar; the range is 401,000 mbar. |
| 16 | The G 1/4 female connection with flange is limited to measuring ranges of 100 bar; the range is 101,000 mbar. |
| 17 | The SAE J514 connection is limited to medium temperatures of -20 degrees C and above, and an extended low-temperature range is ordered. |
| 18 | The angular DIN connectors are IP65; the order requires IP67. |
| 19 | Reverse-polarity protection is not available with the ratiometric output. |
| 20 | The DNV and cULus approvals are not available with the -40 to +100 degrees C medium temperature range. |
| 21 | The loop load of 801 ohm is above the maximum load of 800 ohm at this supply voltage. |
| 22 | The peak operating pressure of 20,001 mbar is above the overpressure limit of 20,000 mbar for this range. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 20 WIKA A-10 pressure transmitters with a gauge range of 0 to 16 bar, a 1 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of -40 to +100 degrees C, with the standard 0.5 % non-linearity, with the DNV approval, a peak operating pressure of 20 bar. The quote states an overpressure limit of 32 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 20 WIKA A-10 pressure transmitters with a gauge range of 0 to 16 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of -40 to +100 degrees C on a housed site protected from condensation, with the standard 0.5 % non-linearity, a peak operating pressure of 20 bar and a loop load of 600 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 32 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/8 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 female with flange process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 1,200 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 40 WIKA A-10 pressure transmitters with a gauge range of 0 to 600 bar, a 4 to 20 mA output powered at 24 V DC, a G 1/4 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity, a peak operating pressure of 1,100 bar and a loop load of 700 ohm. The quote states a maximum load of 800 ohm and an overpressure limit of 1,200 bar. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 4 to 20 mA output powered at 31 V DC (the 8 to 35 V DC option), a G 1/4 B process connection and a angular DIN EN 175301-803 A connector, for a medium temperature of 0 to 80 degrees C, with the improved 0.25 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar and a loop load of 900 ohm. The quote states a maximum load of 1,150 ohm and an overpressure limit of 8 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 0 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of 0 to 80 degrees C, with the improved 0.25 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar. The quote states an overpressure limit of 8 bar. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 12 WIKA A-10 pressure transmitters with a gauge range of 0 to 4 bar, a 0 to 5 V output powered at 24 V DC, a G 1/4 B process connection and a M12x1 4-pin connector, for a medium temperature of 0 to 80 degrees C, with the standard 0.5 % non-linearity and a requirement for IP67 protection, a peak operating pressure of 6 bar. The quote states an overpressure limit of 8 bar. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.