Predictika · EV charger quotes

An AI sales agent's EV charger quote, checked before it goes out

An AI sales agent prepares a quote for Pulsar Max home and workplace EV chargers: tethered or socket, the cable, the power level, the charging current, the energy-management options and the site temperature. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published datasheet and returns a verdict, every reason and the figures it computed.

Scope: Wallbox Pulsar Max tethered and socket EV chargers (7.4, 11 and 22 kW) with their cable, current, energy-management options and operating temperature. See everything this validator covers

This validator models quotes for the Pulsar Max tethered and socket chargers as published in the Wallbox Pulsar Max Tethered/Socket technical datasheet (version EN_b, 06/25, read October 9, 2026), not just the scenarios shown below.

  • Installation and cable — a tethered charger comes with a 5 m or 7 m cable; the socket version (Type 2 with shutter) has no cable, so a cable length on a socket order is an error.
  • Power and current — 7.4 kW is single phase at 230 V and 32 A, 11 kW is three phase at 400 V and 16 A, and 22 kW is three phase at 400 V and 32 A. The charging current can be set from 6 A up to the rated current of the power chosen, and the phases and rated current the quote states must match the power level.
  • Options and site — dynamic load management, solar charging and external MID metering each require an external meter; the input cable is up to 13 mm²; the operating range is −30 °C to 50 °C, and above 40 °C the charger may derate, which goes to a person.

Any quote for a Pulsar Max tethered or socket charger that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are published in the datasheet, so this validator produces no price build-up or line-item quote), other Wallbox chargers (Commander, Quasar, Supernova and others), the part number structure (the datasheet table could not be read with certainty), the UK O-PEN protection and welding-protection options, accessories and installation. Assumption: the colour (white or black) is a free choice.

The AI sales agentBuilds the EV charger quote from the conversation and says it is ready.
Predictika validatorChecks every rule at once and returns the verdict, each finding, and the computed figures.

7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch

What the agent proposes

The AI sales agent says

Illustrative agent statement. The validator receives the structured request below.

Proposing agent: AI sales agent (scripted)

Before sending, the agent must call Recorded run

Predictika validator


      
Waiting for the call.

Where rules-based CPQ gets it wrong

Click to expand

Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.

What the validator caughtTypical rules-based CPQPredictika
A cable length that applies only to one versionOnly with care
A rule can hide or reject the cable field for the socket version, but it has to be written and kept in step for each product variant.
The cable is checked against the installation type with everything else.
A current limit that depends on the power levelOnly with workarounds
The allowed range depends on the power chosen, so it needs a cross-field rule, and the rated current and phases the quote states have to be compared with the right values.
The rated current and phases are computed from the power level and compared with what the quote states.
A site temperature with a hard limit and a soft limitOnly with workarounds
Blocking outside the operating range while sending a warm-site quote to a person needs an approval route that a typical product rule does not provide.
The out-of-range case blocks and the derating case goes to a person with the reason, in the same answer.
Every problem returned in one answerOnly with workarounds
Rules tend to fire as the quote is saved or a step is completed, so a rep often fixes one error and meets the next.
All findings come back together, whatever order the choices arrived in.

What this validator catches: findings from its test cases

Click to expand

Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.

1A tethered Pulsar Max is quoted with a 6 m cable; the datasheet lists 5 m or 7 m.
2A tethered Pulsar Max is quoted with a 0 m cable; the datasheet lists 5 m or 7 m.
3The socket version has no cable, but the quote lists a 5 m cable; cable length applies to the tethered version only.
4The quote sets the charging current to 33 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen.
5The quote sets the charging current to 17 A; the configurable range is 6 A up to the rated current, which is 16 A for the power chosen.
6The quote sets the charging current to 5 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen.
7Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter.
8The quote has an input cable of 14 mm²; the datasheet allows up to 13 mm².
9At a site ambient temperature of 41 °C the charger may derate above 40 °C; a person should confirm that is acceptable.
10At a site ambient temperature of 50 °C the charger may derate above 40 °C; a person should confirm that is acceptable.
11The site ambient temperature of 51 °C is outside the operating range of −30 °C to 50 °C.
12The site ambient temperature of −31 °C is outside the operating range of −30 °C to 50 °C.
13The quote states a rated current of 16 A; this power level has a rated current of 32 A.
14The quote states 3 phases; this power level is 1 phase.
15The quote states a rated current of 32 A; this power level has a rated current of 16 A.
16The socket version has no cable, but the quote lists a 7 m cable; cable length applies to the tethered version only.
17The quote sets the charging current to 40 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen.
18The quote has an input cable of 16 mm²; the datasheet allows up to 13 mm².
19The site ambient temperature of 55 °C is outside the operating range of −30 °C to 50 °C.
20The quote states 1 phase; this power level is 3 phases.

Scenarios and results

Click to expand

The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.

1. Socket order and energy management: Socket chargers with a cable, a current above the rating and load management without a meter

The agent's request. Please quote 6 Pulsar Max socket chargers in white, 11 kW three-phase 400 V, with a 5 m cable, with the charging current set to 20 A and a 6 mm² input cable, for a site at 25 °C. The order includes dynamic load management. The quote states 3 phases. It is ready to send.

Verdict: Blocked.

  • Socket version with a cable. The socket version has no cable, but the quote lists a 5 m cable; cable length applies to the tethered version only.
  • Charging current outside the configurable range. The quote sets the charging current to 20 A; the configurable range is 6 A up to the rated current, which is 16 A for the power chosen.
  • Energy-management option without an external meter. Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter.

2. Socket order and energy management: The agent resubmits after fixing the errors

The agent's request. Please quote 6 Pulsar Max socket chargers in white, 11 kW three-phase 400 V, with no cable, with the charging current set to 16 A and a 6 mm² input cable, for a site at 25 °C. The order includes dynamic load management and an external meter. The quote states a rated current of 16 A and 3 phases. It is ready to send.

Verdict: Allowed.

  • Charger summary. 6 chargers, 3 phases at 400 V, rated current 16 A, charging current set to 16 A; no prices are modeled.

3. Single-phase order with solar charging: Single-phase order with a cable not offered, a high current, solar charging without a meter and the wrong phases

The agent's request. Please quote 2 Pulsar Max tethered chargers in white, 7.4 kW single-phase 230 V, with a 6 m cable, with the charging current set to 40 A and a 6 mm² input cable, for a site at 45 °C. The order includes solar charging. The quote states 3 phases. It is ready to send.

Verdict: Blocked.

  • Tethered cable length not offered. A tethered Pulsar Max is quoted with a 6 m cable; the datasheet lists 5 m or 7 m.
  • Charging current outside the configurable range. The quote sets the charging current to 40 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen.
  • Energy-management option without an external meter. Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter.
  • Stated phases do not match. The quote states 3 phases; this power level is 1 phase.
  • Derating above 40 C. At a site ambient temperature of 45 °C the charger may derate above 40 °C; a person should confirm that is acceptable.

4. Single-phase order with solar charging: The agent resubmits after fixing the errors

The agent's request. Please quote 2 Pulsar Max tethered chargers in white, 7.4 kW single-phase 230 V, with a 7 m cable, with the charging current set to 40 A and a 6 mm² input cable, for a site at 45 °C. The order includes solar charging. The quote states 1 phase. It is ready to send.

Verdict: Blocked.

  • Charging current outside the configurable range. The quote sets the charging current to 40 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen.
  • Energy-management option without an external meter. Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter.
  • Derating above 40 C. At a site ambient temperature of 45 °C the charger may derate above 40 °C; a person should confirm that is acceptable.

5. Single-phase order with solar charging: The agent resubmits after fixing the errors

The agent's request. Please quote 2 Pulsar Max tethered chargers in white, 7.4 kW single-phase 230 V, with a 7 m cable, with the charging current set to 32 A and a 6 mm² input cable, for a site at 35 °C. The order includes solar charging and an external meter. The quote states a rated current of 32 A and 1 phase. It is ready to send.

Verdict: Allowed.

  • Charger summary. 2 chargers, 1 phase at 230 V, rated current 32 A, charging current set to 32 A; no prices are modeled.

6. Large socket order on a hot site: Ten socket chargers with an oversized input cable on a very hot site

The agent's request. Please quote 10 Pulsar Max socket chargers in black, 22 kW three-phase 400 V, with no cable, with the charging current set to 32 A and a 16 mm² input cable, for a site at 52 °C. The quote states a rated current of 32 A and 3 phases. It is ready to send.

Verdict: Blocked.

  • Input cable too large. The quote has an input cable of 16 mm²; the datasheet allows up to 13 mm².
  • Ambient temperature outside the operating range. The site ambient temperature of 52 °C is outside the operating range of −30 °C to 50 °C.

7. Large socket order on a hot site: The agent resubmits after fixing the errors

The agent's request. Please quote 10 Pulsar Max socket chargers in black, 22 kW three-phase 400 V, with no cable, with the charging current set to 32 A and a 10 mm² input cable, for a site at 35 °C. The quote states a rated current of 32 A and 3 phases. It is ready to send.

Verdict: Allowed.

  • Charger summary. 10 chargers, 3 phases at 400 V, rated current 32 A, charging current set to 32 A; no prices are modeled.

Narration transcript

Click to expand

The text of the narrated walkthrough, step by step.

  1. Welcome to a demo of Predictika's Validator. An AI sales agent prepares a quote for Pulsar Max home and workplace EV chargers: tethered or socket, the cable, the power level, and more. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published datasheet and returns a verdict, every reason and the figures it computed.
  2. I will start with the first request by the agent.
  3. The agent says. Please quote 2 Pulsar Max tethered chargers in white, 7.4 kW single-phase 230 V, with a 6 m cable, with the charging current set to 40 A and a 6 mm² input cable. The order includes solar charging. The rest of the request is on screen.
  4. Before it goes out, the agent calls the validator.
  5. Blocked, with four findings and one approval, all in one answer. A tethered Pulsar Max is quoted with a 6 m cable; the datasheet lists 5 m or 7 m. The quote sets the charging current to 40 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen. Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter. The other one is on screen.
  6. The validator returned four blocking findings and one approval in one answer. A check that reads one field at a time would pass most of this; it shows only when the choices in the quote are checked against each other.
  7. What this shows: for a cable length that applies only to one version, a rules-based CPQ is error-prone for this.
  8. Now the agent resubmits.
  9. The corrected request. It changes the cable length to 7 m and the stated phases to 1.
  10. It calls the validator again.
  11. Still blocked, with two findings and one approval, all in one answer. The quote sets the charging current to 40 A; the configurable range is 6 A up to the rated current, which is 32 A for the power chosen. Dynamic load management, solar charging or external MID metering is quoted without an external meter; the datasheet says these options require an external meter.
  12. Two findings cleared. Still blocking: charging current outside the configurable range and energy-management option without an external meter. One approval also remains for a person: derating above 40 C.
  13. The agent resubmits once more.
  14. The revised request. It changes the charging current to 32 A, the site ambient temperature to 35 and the external meter to yes. It sets the stated rated current to 32 A.
  15. It calls the validator once more.
  16. This time the validator clears it.
  17. All three earlier findings are cleared.
  18. Five problems caught in one call, fixed in two passes, and a clean quote. That is the value of Predictika's validator: catching mistakes before they reach the customer. Now you can try the other scenarios yourself.