Predictika · Temperature controller orders
An AI sales agent prepares an order for a Watlow EZ-ZONE PM panel mount controller, the PID model or the integrated PID model, with its package size, controller function, outputs, communications and options. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the ordering tables in the public EZ-ZONE PM specification sheets, and returns a verdict, every reason and the figures it computed.
This validator models orders for the EZ-ZONE PM PID model and the integrated PID model in the 1/32, 1/16, 1/8 and 1/4 DIN sizes, not just the scenarios shown below.
Any EZ-ZONE PM order that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are published in the sources), the PM Express and standalone limit models, custom firmware, the two digital I/O point power options as a separate need, and other Watlow product lines.
8 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| An option that the package size does not offer | Only with care Availability depends on the size, so each option needs its own size rule and every new combination has to be added. | Package size and every option arrive in one request and are checked together on every call. |
| A communications option that rules out other options on 1/16 DIN | Only with workarounds One digit of the part number restricts two others, and rules usually check one choice at a time. | The communications option, auxiliary function and outputs 3 and 4 are compared on every call, in any order. |
| Class 1 Division 2 with the wrong output types | Only with care The exclusion depends on letters inside the output code, so lookup tables are needed. | The output codes and the option are compared together, including the integrated limit. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The integrated controller is offered only in the 1/16, 1/8 and 1/4 DIN sizes, not in 1/32 DIN. |
| 2 | The profiling controller with battery backup and real-time clock is not available in the 1/32 DIN or 1/16 DIN sizes. |
| 3 | The 15 A NO-ARC power output is not a valid selection in the 1/32 DIN size. |
| 4 | The Bluetooth communications options are offered on the 1/16 DIN size only. |
| 5 | Bluetooth is not available in all countries; a person should confirm availability for the destination country with the factory. |
| 6 | The 6 digital I/O communications options are not available on 1/16 DIN modules. |
| 7 | The PID model offers only no option, Bluetooth, EIA 485 Modbus RTU, or both; the chosen communications option belongs to the integrated model. |
| 8 | The PID model has no auxiliary control function, no outputs 3 and 4 and no enhanced firmware; these belong to the integrated model. |
| 9 | The second PID channel auxiliary function is not available on 1/16 DIN models. |
| 10 | On 1/16 DIN models a fieldbus communications option requires no auxiliary function and no outputs 3 and 4. |
| 11 | On 1/16 DIN models the output 3 and 4 options with the 15 A NO-ARC power output are not valid. |
| 12 | The current transformer input cannot be combined with a universal process output on outputs 3 and 4. |
| 13 | An integrated limit controller is valid only with a mechanical relay on output 4 (output 3 and 4 codes CJ, EJ or AJ). |
| 14 | The Class 1, Division 2 option is not available with a mechanical relay or NO-ARC output type (letters E, H or J in the output code) or with an integrated limit. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote a Watlow EZ-ZONE PM PID controller in the 1/32 DIN size as a PID controller with universal input, ramp/soak profiling, battery backup and real-time clock, with a 100 to 240 VAC power supply, outputs 1 and 2 of switched dc/open collector as the first and NO-ARC 15 A power control as the second, no communications option and the standard EZ-ZONE PM face plate. The site has a mains (100 to 240 VAC) supply and a universal-input (thermocouple, RTD or process) sensor, and the customer needs 2 control outputs, ramp/soak profiling and a real-time clock with battery backup. The quote states 2 outputs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Watlow EZ-ZONE PM PID controller in the 1/8 DIN horizontal size as a PID controller with universal input, ramp/soak profiling, battery backup and real-time clock, with a 100 to 240 VAC power supply, outputs 1 and 2 of switched dc/open collector as the first and NO-ARC 15 A power control as the second, no communications option and the standard EZ-ZONE PM face plate. The site has a mains (100 to 240 VAC) supply and a universal-input (thermocouple, RTD or process) sensor, and the customer needs 2 control outputs, ramp/soak profiling and a real-time clock with battery backup. The quote states 2 outputs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/16 DIN size as a PID controller with universal input, with a 100 to 240 VAC plus 2 digital I/O points power supply, outputs 1 and 2 of mechanical relay 5 A Form C as the first and mechanical relay 5 A Form A as the second, outputs 3 and 4 of switched dc/open collector as the first and NO-ARC 15 A power control as the second, EtherNet/IP and Modbus TCP with Bluetooth, auxiliary function: second PID channel (universal input), enhanced firmware and the Class 1, Division 2 option. The site has a mains (100 to 240 VAC) supply and a universal-input (thermocouple, RTD or process) sensor, and the customer needs 4 control outputs, 2 PID loops and cascade control. The quote states 4 outputs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/8 DIN vertical size as a PID controller with universal input, with a 100 to 240 VAC plus 2 digital I/O points power supply, outputs 1 and 2 of mechanical relay 5 A Form C as the first and mechanical relay 5 A Form A as the second, outputs 3 and 4 of switched dc/open collector as the first and NO-ARC 15 A power control as the second, EtherNet/IP and Modbus TCP with Bluetooth, auxiliary function: second PID channel (universal input), enhanced firmware and the Class 1, Division 2 option. The site has a mains (100 to 240 VAC) supply and a universal-input (thermocouple, RTD or process) sensor, and the customer needs 4 control outputs, 2 PID loops and cascade control. The quote states 4 outputs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/8 DIN vertical size as a PID controller with universal input, with a 100 to 240 VAC plus 2 digital I/O points power supply, outputs 1 and 2 of switched dc/open collector as the first and SSR Form A 0.5 A as the second, outputs 3 and 4 of switched dc/open collector as the first and switched dc as the second, EtherNet/IP and Modbus TCP, auxiliary function: second PID channel (universal input), enhanced firmware and the Class 1, Division 2 option. The site has a mains (100 to 240 VAC) supply and a universal-input (thermocouple, RTD or process) sensor, and the customer needs 4 control outputs, 2 PID loops and cascade control. The quote states 4 outputs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/16 DIN size as a PID controller with thermistor input, with a 20 to 28 VAC or 12 to 40 VDC power supply, outputs 1 and 2 of switched dc/open collector as the first and switched dc as the second, outputs 3 and 4 of switched dc/open collector as the first and mechanical relay 5 A Form A as the second, Bluetooth, auxiliary function: none, standard firmware and the standard EZ-ZONE PM face plate. The site has a low-voltage (20 to 28 VAC or 12 to 40 VDC) supply and a thermistor sensor, and the customer needs 4 control outputs, heater current monitoring. The quote states 3 outputs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/16 DIN size as a PID controller with thermistor input, with a 20 to 28 VAC or 12 to 40 VDC power supply, outputs 1 and 2 of switched dc/open collector as the first and switched dc as the second, outputs 3 and 4 of switched dc/open collector as the first and mechanical relay 5 A Form A as the second, Bluetooth, auxiliary function: current transformer input, standard firmware and the standard EZ-ZONE PM face plate. The site has a low-voltage (20 to 28 VAC or 12 to 40 VDC) supply and a thermistor sensor, and the customer needs 4 control outputs, heater current monitoring. The quote states 4 outputs. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote a Watlow EZ-ZONE PM integrated PID controller in the 1/16 DIN size as a PID controller with thermistor input, with a 20 to 28 VAC or 12 to 40 VDC power supply, outputs 1 and 2 of switched dc/open collector as the first and switched dc as the second, outputs 3 and 4 of switched dc/open collector as the first and mechanical relay 5 A Form A as the second, EIA 485 Modbus RTU, auxiliary function: current transformer input, standard firmware and the standard EZ-ZONE PM face plate. The site has a low-voltage (20 to 28 VAC or 12 to 40 VDC) supply and a thermistor sensor, and the customer needs 4 control outputs, heater current monitoring. The quote states 4 outputs. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.