Predictika · Terminal block orders
An AI sales agent prepares an order for a Weidmüller Klippon Connect A2C feed-through terminal block with a block size, a solid conductor, a circuit current and voltage, and whether the panel needs UL ratings. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the values Weidmüller publishes in the data sheets for these blocks and returns a verdict, every reason and the figures it computed.
This validator models orders for five Klippon Connect A2C feed-through terminal blocks, not just the scenarios shown below.
Any order for these five blocks that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (none are public, so this validator produces no price build-up or line-item quote), stranded and ferrule-terminated conductors (the data sheet readings were not consistent enough to model), UL size C and D ratings, other Klippon Connect and Weidmüller product lines, accessories, marking and approvals such as ATEX. Assumptions: the UL (cURus) ratings used are the size B figures, and the values are those read from the data sheets in October 2026.
6 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Ratings that differ by block size | Only with care Every block has its own conductor range, current and voltage, so each needs a table row and a rule that reads it. | The block and the circuit are in one request; the ratings are looked up and compared on every call. |
| A UL rating that is lower than the nominal rating | Only with care A second set of limits that applies only when UL use is chosen, which interacts with the plain rating rules. | UL use, current and voltage are in one request and the UL rule is checked with all the others. |
| A stated rating that disagrees with the data sheet | Only with workarounds The listed value is derived from the block; checking a stated figure against it takes extra formulas that interact with the rest of the rules. | The stated current is a field in the request and is compared with the listed value. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The order has a solid conductor of 2.51 mm²; this block connects solid conductors up to 2.5 mm². |
| 2 | The order has a solid conductor of 0.13 mm²; this block connects solid conductors from 0.14 mm². |
| 3 | The circuit carries 25 A; this block has a nominal current of 24 A. |
| 4 | The circuit runs at 801 V; this block has a rated voltage of 800 V. |
| 5 | The order has a solid conductor of 4.01 mm²; this block connects solid conductors up to 4 mm². |
| 6 | The circuit carries 33 A; this block has a nominal current of 32 A. |
| 7 | The order has a solid conductor of 0.49 mm²; this block connects solid conductors from 0.5 mm². |
| 8 | The order has a solid conductor of 6.01 mm²; this block connects solid conductors up to 6 mm². |
| 9 | The circuit carries 42 A; this block has a nominal current of 41 A. |
| 10 | The circuit carries 58 A; this block has a nominal current of 57 A. |
| 11 | The circuit runs at 1,001 V; this block has a rated voltage of 1,000 V. |
| 12 | The order has a solid conductor of 16.01 mm²; this block connects solid conductors up to 16 mm². |
| 13 | The circuit carries 77 A; this block has a nominal current of 76 A. |
| 14 | For UL use the circuit carries 21 A; the listed UL (cURus) current for this block is 20 A. |
| 15 | For UL use the circuit runs at 601 V; the listed UL (cURus) voltage for these blocks is 600 V. |
| 16 | For UL use the circuit carries 63 A; the listed UL (cURus) current for this block is 62 A. |
| 17 | The circuit carries 30 A; this block has a nominal current of 24 A. |
| 18 | The order states a nominal current of 32 A, but the listed nominal current for this block is 24 A. |
| 19 | The order states a nominal current of 57 A, but the listed nominal current for this block is 76 A. |
| 20 | The order has a solid conductor of 0.1 mm²; this block connects solid conductors from 0.14 mm². |
| 21 | The circuit runs at 900 V; this block has a rated voltage of 800 V. |
| 22 | The order states a nominal current of 41 A, but the listed nominal current for this block is 24 A. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please prepare an order for a Weidmüller A2C 4 terminal block with a 6 mm² solid conductor, in a circuit carrying 40 A at 800 V, with no UL requirement. The order states a nominal current of 32 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for a Weidmüller A2C 10 terminal block with a 6 mm² solid conductor, in a circuit carrying 40 A at 800 V, with no UL requirement. The order states a nominal current of 57 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare an order for a Weidmüller A2C 10 terminal block with a 10 mm² solid conductor, in a circuit carrying 50 A at 800 V, for UL use. The order states a nominal current of 57 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for a Weidmüller A2C 10 terminal block with a 10 mm² solid conductor, in a circuit carrying 50 A at 600 V, for UL use. The order states a nominal current of 57 A. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare an order for a Weidmüller A2C 6 terminal block with a 0.3 mm² solid conductor, in a circuit carrying 45 A at 1,000 V, with no UL requirement. The order states a nominal current of 57 A. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare an order for a Weidmüller A2C 10 terminal block with a 5 mm² solid conductor, in a circuit carrying 45 A at 1,000 V, with no UL requirement. The order states a nominal current of 57 A. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.