Predictika · Elevator landing door configuration checks
An AI sales agent assembles a landing door order for a new elevator project: the door model, the closing system, the clear opening width and height, the elevator rated speed, the number of elevators and landings, and options such as full glass or an EN 81-58 EI fire rating. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the public landing door comparison table and returns a verdict, every reason and the figures it computed.
This validator models the public landing door comparison table for nine door models, not just the scenarios shown below.
Any order for these nine door models that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (Wittur publishes none, so no price build-up or line-item quote is produced), car doors, drive systems, frames and other accessories. Assumptions: the Pegasus Skyline (listed as over 6 m/s) and the Sematic 2000 B-HR (over 5 m/s) are given no upper speed limit; the Hydra 3000 is read as offering the Spring or Counterweight closing system; full glass on the Sematic 2000 B-HR is listed as optional (limited) and the EI rating is not listed for the Hydra 3000, so both go to a person rather than being blocked.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Options listed for some door models only, such as full glass or the EN 81-58 EI rating | Only with care Each option has to be tied to the models that list it, and the table kept in step as the range changes. | The model and every option requested are in one request and compared together on every call. |
| Opening width and height ranges that differ by model | Only with care A width and a height range per model, each with a lower and an upper bound. | The model and the opening are in one request, and every limit is checked on every call. |
| A stated door count that disagrees with elevators times landings | Only with workarounds The total comes from a multiplication; checking a stated figure against it takes extra formulas. | The stated figure is one more field in the request and is compared with the computed total on every call. |
| A closing system that a model does not list | Easy A compatibility rule between the closing system and the model; routine in a product-rules CPQ. | The same rule, checked together with all the others on every call. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The clear opening is 3,300 mm; this model goes up to 3,200 mm. |
| 2 | The clear opening is 550 mm; this model starts at 600 mm. |
| 3 | The clear height is 3,900 mm; this model goes up to 3,800 mm. |
| 4 | The clear height is 1,950 mm; this model starts at 2,000 mm. |
| 5 | The elevator rated speed is 5.5 m/s; this model is listed up to 5.0 m/s. |
| 6 | The clear opening is 1,900 mm; this model goes up to 1,800 mm. |
| 7 | This closing system is not in the published list for the quoted door model. |
| 8 | The elevator rated speed is 2.5 m/s; this model is listed up to 2.0 m/s. |
| 9 | The clear opening is 1,200 mm; this model goes up to 1,100 mm. |
| 10 | The elevator rated speed is 3.6 m/s; this model is listed up to 3.5 m/s. |
| 11 | The EN 81-58 EI fire rating is not listed as an option for the quoted door model. |
| 12 | Full glass panels are not listed as an option for the quoted door model. |
| 13 | The clear opening is 900 mm; this model starts at 1,000 mm. |
| 14 | Full glass for the Sematic 2,000 B-HR could not be fully confirmed from the public table; a person should confirm it for this order. |
| 15 | EN 81-58 EI for the Hydra 3,000 could not be confirmed from the public table; a person should confirm it for this order. |
| 16 | The order states 14 landing doors in total; the elevators and landings give 12. |
| 17 | The clear opening is 2,000 mm; this model goes up to 1,800 mm. |
| 18 | The clear height is 3,200 mm; this model goes up to 3,000 mm. |
| 19 | The elevator rated speed is 3.5 m/s; this model is listed up to 3.0 m/s. |
| 20 | The order states 10 landing doors in total; the elevators and landings give 12. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please prepare a landing door order for 3 elevators with 8 landings each, using the Wittur Hydra 3000 door with the spring closing system, a clear opening of 1,100 mm wide and 2,100 mm high. The elevators are rated at 4.0 m/s. The order states 24 landing doors in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a landing door order for 3 elevators with 8 landings each, using the Wittur Hydra door with the spring closing system, a clear opening of 1,100 mm wide and 2,100 mm high. The elevators are rated at 4.0 m/s. The order states 24 landing doors in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a landing door order for 2 elevators with 5 landings each, using the Wittur Luna door with the counterweight closing system, a clear opening of 1,400 mm wide and 2,400 mm high. The elevators are rated at 2.5 m/s, and the doors should have the EN 81-58 EI fire rating. The order states 10 landing doors in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a landing door order for 2 elevators with 5 landings each, using the Wittur Sematic 2000 B-HR door with the counterweight closing system, a clear opening of 1,400 mm wide and 2,400 mm high. The elevators are rated at 2.5 m/s, and the doors should have the EN 81-58 EI fire rating. The order states 10 landing doors in total. It is ready to send.
Verdict: Allowed.
The agent's request. Please prepare a landing door order for 2 elevators with 6 landings each, using the Wittur Augusta Evo door with the spring closing system, a clear opening of 1,200 mm wide and 2,100 mm high. The elevators are rated at 1.6 m/s, and the doors should have full glass panels. The order states 12 landing doors in total. It is ready to send.
Verdict: Blocked.
The agent's request. Please prepare a landing door order for 2 elevators with 6 landings each, using the Wittur Sematic 2000 B-HR door with the spring closing system, a clear opening of 1,100 mm wide and 2,100 mm high. The elevators are rated at 1.6 m/s, and the doors should have full glass panels. The order states 12 landing doors in total. It is ready to send.
Verdict: Needs approval.
The agent's request. Please prepare a landing door order for 2 elevators with 6 landings each, using the Wittur Hydra door with the spring closing system, a clear opening of 1,100 mm wide and 2,100 mm high. The elevators are rated at 1.6 m/s, and the doors should have full glass panels. The order states 12 landing doors in total. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.