An AI sales agent prepares an order for ClarkDietrich ProSTUD drywall studs: stud size and thickness, spacing, lateral load, deflection limit, bracing, wall height, coating and web stiffeners, plus the limiting height and weight the quote states. Before it goes out, the agent sends it to Predictika, which checks it against a declarative model of the published catalog tables and returns a verdict, every reason and the figures it computed.
This validator models non-composite ProSTUD drywall stud orders across the catalog's limiting height tables, not just the scenarios shown below.
Any order for these studs that touches these rules is in scope — not only the scenarios pictured here. Not covered: prices (the catalog has none, so there is no price build-up), track and other accessories, structural design of the wall, and composite wall limiting heights.
7 scenarios in 3 groups · each group runs from the agent’s first attempt to the outcome · click one to switch
Illustrative agent statement. The validator receives the structured request below.
Proposing agent: AI sales agent (scripted)
Before sending, the agent must call Recorded run
What this means
Our assessment of what a typical rules-based CPQ (product rules, price rules and validation rules, as in Salesforce CPQ) does with the same cases. It is a judgment about effort and reliability, not a claim that nothing can be built.
| What the validator caught | Typical rules-based CPQ | Predictika |
|---|---|---|
| Limiting heights from a large table | Only with workarounds Each combination of stud size, thickness, spacing, load, deflection limit and bracing has its own published height; that is a table of more than a thousand entries to load and keep current. | The catalog values are the model, and the height for the chosen combination is looked up and compared on every call. |
| Stiffeners that depend on the stud | Only with care Whether stiffeners are called for depends on the stud size and thickness, so a rule has to be written for each affected stud. | The stud selects the stiffener requirement, and a missing stiffener comes back as its own finding. |
| Stated figures that must match the order | Only with care A stated limiting height or weight is a free-entry figure; a rule can compare it with the catalog value, but someone has to write and maintain that comparison. | The stated figures travel with the order and are compared with the computed figures on every call. |
| Coatings and market availability | Only with care Coatings other than the standard one and the thicker studs are special order or select-market items; these are approvals, not hard stops. | Each one returns an approval finding that names what a person should confirm. |
| Every problem returned in one answer | Only with workarounds Rules tend to fire as the order is saved or a step is completed, so a rep often fixes one error and meets the next. | All findings come back together, whatever order the choices arrived in. |
Every rule is checked on every call, in any order the choices arrive; one problem never hides another. Blocking findings stop the quote; approval findings need a person to sign off; everything else is computed.
| 1 | The wall is 159 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 158 in. |
| 2 | ProSTUD 30MIL and 33MIL are available in select markets only, so a person should confirm availability. |
| 3 | The wall is 120 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 80 in. |
| 4 | The wall is 90 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 79 in. |
| 5 | The catalog requires web stiffeners at bearing points for this stud, and the order has none. |
| 6 | The wall is 130 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 129 in. |
| 7 | The wall is 140 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 110 in. |
| 8 | The wall is 150 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 138 in. |
| 9 | Composite wall limiting heights apply only when the wall is built as tested per AISI S916 and ICC-ES AC86, and this validator does not check them, so a person should confirm the height with ClarkDietrich. |
| 10 | G40EQ is the standard coating; G40 is available on request and G60, G90 and G40EQ DiamondPlus are special order (DiamondPlus only in select markets and thicknesses), so a person should confirm availability. |
| 11 | The quote states a limiting height of 160 in, but the catalog value for this stud and wall is 158 in. |
| 12 | The quote states 100 lb of studs, but 120 studs of this size at this wall height weigh 516 lb. |
| 13 | The order has no studs. |
| 14 | The wall is 300 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 195 in. |
| 15 | The wall is 300 in high, but the catalog limiting height for the selected stud, spacing, load, deflection limit and bracing is 200 in. |
| 16 | The quote states a limiting height of 400 in, but the catalog value for this stud and wall is 200 in. |
| 17 | The quote states 1 lb of studs, but 120 studs of this size at this wall height weigh 1,440 lb. |
The recorded result of the validator for each scenario on this page: the request the AI agent sent, the verdict, and every finding, in the order they appear above.
The agent's request. Please quote 240 ProSTUD drywall studs, 6 in web, 18 mil, 24 in on center, for a 178 in high non-composite wall. The design is a 7.5 psf lateral load at a L/240 deflection limit with full bracing, with no web stiffeners, in G40EQ coating. The quote states a limiting height of 166 in and 2,100 lb of studs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 240 ProSTUD drywall studs, 6 in web, 18 mil, 16 in on center, for a 178 in high non-composite wall. The design is a 7.5 psf lateral load at a L/240 deflection limit with full bracing, with web stiffeners, in G40EQ coating. The quote states a limiting height of 196 in and 2,100 lb of studs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 300 ProSTUD drywall studs, 3-5/8 in web, 15 mil, 24 in on center, for a 120 in high non-composite wall. The design is a 5 psf lateral load at a L/240 deflection limit with bracing at 48 in, with no web stiffeners, in G90 coating. The quote states a limiting height of 105 in and 1,050 lb of studs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 300 ProSTUD drywall studs, 3-5/8 in web, 15 mil, 16 in on center, for a 120 in high non-composite wall. The design is a 5 psf lateral load at a L/240 deflection limit with bracing at 48 in, with web stiffeners, in G90 coating. The quote states a limiting height of 129 in and 1,050 lb of studs. It is ready to send.
Verdict: Needs approval.
The agent's request. Please quote 300 ProSTUD drywall studs, 3-5/8 in web, 15 mil, 16 in on center, for a 120 in high non-composite wall. The design is a 5 psf lateral load at a L/240 deflection limit with bracing at 48 in, with web stiffeners, in G40EQ coating. The quote states a limiting height of 129 in and 1,050 lb of studs. It is ready to send.
Verdict: Allowed.
The agent's request. Please quote 180 ProSTUD drywall studs, 1-5/8 in web, 18 mil, 12 in on center, for a 66 in high non-composite wall. The design is a 7.5 psf lateral load at a L/360 deflection limit with full bracing, with web stiffeners, in G40EQ coating. The quote states a limiting height of 96 in and 287 lb of studs. It is ready to send.
Verdict: Blocked.
The agent's request. Please quote 180 ProSTUD drywall studs, 1-5/8 in web, 18 mil, 12 in on center, for a 66 in high non-composite wall. The design is a 7.5 psf lateral load at a L/360 deflection limit with full bracing, with web stiffeners, in G40EQ coating. The quote states a limiting height of 71 in and 287 lb of studs. It is ready to send.
Verdict: Allowed.
The text of the narrated walkthrough, step by step.